Dosimetric feasibility of stereotactic irradiation of primary prostate cancer at 5x9 Gy with a method of urethral sparing.

Benhmida Salim, Beneux Amandine, Udrescu Corina, Rouviere Olivier, Horn Samy, Enachescu Ciprian, Lapierre Ariane, Chapet Olivier

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

The most commonly used dose for prostate cancer stereotactic body radiotherapy (SBRT) is 5 × 7.25 Gy. The aim of this study was to evaluate the dosimetric feasibility of a 5 × 9 Gy SBRT regimen while still limiting the dose to the urethra to 5 × 7.25 Gy. This dosimetric study is part of the groundwork for a future Phase III randomized trial.

METHODS

The prostate, the urethra and the tumors were delineated on 20 dosimetric CT-scans with MRI-registration. The planning target volume (PTVp) was defined as a 5 mm expansion (3 mm posteriorly) of the prostate. The planning at risk volume (PRVu) was defined as a 2 mm expansion of the urethra. The tumors were delineated on the MRI (GTVt) and a 3 mm-margin was added to create a tumoral planning target volume (PTVt). IMRT plans were optimized to deliver 5 × 9 Gy to the PTVp, limiting the dose to the PRVu to 5 × 7.25 Gy. Results are presented using average (range) values.

RESULTS

PTVp doses were D98% = 36.2 Gy (35.6-36.8), D2% = 46.9 Gy (46.5-47.5) and mean dose = 44.1 Gy (43.8-44.5). The dose to the PRVu was within tolerance limits for all 20 patients: V34.4Gy = 99.8% (99.2-100) and D5% = 38.7 Gy (38.6-38.8). Dose coverage of PTV-PRVu was D95% = 40.6 Gy (40.5-40.9), D5% = 46.6 Gy (46.2-47.2) and mean dose = 44.6 Gy (44.3-44.9). Dose to the PTVt reached 44.6 Gy (41.2-45.9). Doses to the OAR were respected, except V36Gy ≤1 cc for the rectum.

CONCLUSION

A SBRT dose-escalation to 5 × 9 Gy on the prostate while sparing the urethra + 2 mm at 36.25 Gy is feasible without compromising dose coverage to the tumor. This radiation regimen will be used for a Phase-III trial.

ADVANCES IN KNOWLEDGE: In prostate SBRT, dose optimization on the urethra is feasible and could decrease urinary toxicities.

Для цитирования: Benhmida Salim, Beneux Amandine, Udrescu Corina, Rouviere Olivier, Horn Samy, Enachescu Ciprian, Lapierre Ariane, Chapet Olivier. Dosimetric feasibility of stereotactic irradiation of primary prostate cancer at 5x9 Gy with a method of urethral sparing.. The British journal of radiology. 2021. DOI: 10.1259/bjr.20210142.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.