MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/a-2340-7432

Медицинская библиотека · Endoscopy · 2024

Dedicated cautery-enhanced tubular self-expandable metal stent for endoscopic ultrasound-guided hepaticogastrostomy: feasibility study.

Vargas-Madrigal Jorge, Chan Shannon M, Dhar Jahnvi, Teoh Anthony Y B, Samanta Jayanta, Lakhtakia Sundeep, Giovannini Marc

СтатьяМногоцентровое исследованиеVideo-Audio MediaПеревод пока не подготовлен

Аннотация

BACKGROUND

Endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) is an alternative for biliary drainage in patients with obstructive pancreaticobiliary pathology when endoscopic retrograde cholangiopancreatography (ERCP) is not feasible. Despite its effectiveness, EUS-HGS is associated with a significant risk of adverse events. This study aimed to evaluate the feasibility and safety of a newly designed dedicated cautery-enhanced tubular self-expandable metal stent (SEMS) for EUS-HGS.

METHODS

This multicenter prospective study included patients with malignant biliary obstruction in whom ERCP had failed because of tumor infiltration, inability to drain the intrahepatic ducts, or surgically altered anatomy. A dedicated cautery-enhanced tubular SEMS was used for EUS-HGS. Technical and clinical success rates, procedure times, and adverse events were evaluated.

RESULTS

20 patients underwent EUS-HGS with the dedicated stent. Technical and clinical success rates of 100% were achieved, with no reported severe adverse events or mortality. The median procedure time was 16 minutes. Recurrent biliary obstruction was observed in 1 patient.

CONCLUSIONS

The dedicated cautery-enhanced tubular SEMS for EUS-HGS can simplify the procedure and enhance its safety and efficacy. This innovation shows promise for improving patient outcomes, although further studies are needed to validate these findings in a broader patient population.

Для цитирования: Vargas-Madrigal Jorge, Chan Shannon M, Dhar Jahnvi, Teoh Anthony Y B, Samanta Jayanta, Lakhtakia Sundeep, Giovannini Marc. Dedicated cautery-enhanced tubular self-expandable metal stent for endoscopic ultrasound-guided hepaticogastrostomy: feasibility study.. Endoscopy. 2024. DOI: 10.1055/a-2340-7432.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.