MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2174/0115734056298526240607052138

Медицинская библиотека · Current medical imaging · 2024

Feasibility Study on Constructing Dosimetric Correlated Geometric Parameters for Automatic Segmentation Evaluation.

Zhang Yujie, Zhou Xin, Ji Weixing, Zhang Jianying

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To investigate the feasibility of constructing new geometric parameters that correlate well with dosimetric parameters.

METHODS

100 rectal cancer patients were enrolled. The targets were identified manually, while the organs at risk (bladder, small bowel, left and right femoral heads) were segmented both manually and automatically. The radiotherapy plans were optimized according to the automatically contoured organs at risk. Forty cases were randomly selected to establish the relationship between dose and distance for each organ at risk, termed "dose-distance curves," which were then applied to the new geometric parameters. The correlation between these new geometric parameters and dosimetric parameters was analyzed in the remaining 60 test cases.

RESULTS

The "dose-distance curves" were similar across the four organs at risk, exhibiting an inverse function shape with a rapid decrease initially and a slower rate at a later stage. The Pearson correlation coefficients of new geometric parameters and dosimetric parameters in the bladder, small intestine, and left and right femur heads were 0.96, 0.97, 0.88, and 0.70, respectively.

CONCLUSIONS

The new geometric parameters predicated on "distance from the target" showed a high correlation with corresponding dosimetric parameters in rectal cancer cases. It is feasible to utilize the new geometric parameters to evaluate the dose deviation attributable to automatic segmentation.

Для цитирования: Zhang Yujie, Zhou Xin, Ji Weixing, Zhang Jianying. Feasibility Study on Constructing Dosimetric Correlated Geometric Parameters for Automatic Segmentation Evaluation.. Current medical imaging. 2024. DOI: 10.2174/0115734056298526240607052138.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.