OBJECTIVES

The aim of this clinical study was to compare the accuracy of intraoral scan system (IOS) with prefabricated aids and stereophotogrammetry (SPG) compared with open tray implant impression (OI) for complete-arch implant-supported fixed dental prostheses (CIFDP).

MATERIALS AND

METHODS

Patients needing CIFDP were enrolled in this study. OI, reference standard, IOS with prefabricated aids, and SPG were performed for each patient. Distance and angle deviations between all pairs of abutment analogs, root mean square (RMS) errors between the aligned test and reference model, and chairside time were measured. The effect of inter-abutment distance, jaw (maxilla or mandible), number of implants, and arch length on deviations was analyzed. The mixed effect model was applied to analyze deviations and RMS errors.

RESULTS

Fifteen consecutive individuals (6 females and 9 males, 47-77 years old) with 22 arches (9 upper and 13 lower jaws) and 115 implants were included. There was no significant difference in distance deviation comparing SPG and IOS with OI (p > .05). IOS showed a significantly greater angle deviation and RMS errors than SPG (median 0.40° vs. 0.31°, 69 μm vs. 45 μm, p < .01). The inter-abutment distance was negatively correlated with the accuracy of SPG and IOS (p < .05). The chairside time for IOS, SPG, and OI was 10.49 ± 3.50, 14.71 ± 2.86, and 20.20 ± 3.01 min, respectively (p < .01).

CONCLUSIONS

The accuracy of SPG and IOS with prefabricated aids was comparable. IOS was the most efficient workflow.

Для цитирования: Fu Xiao-Jiao, Liu Min, Liu Bei-Lei, Tonetti Maurizio S, Shi Jun-Yu, Lai Hong-Chang. Accuracy of intraoral scan with prefabricated aids and stereophotogrammetry compared with open tray impressions for complete-arch implant-supported prosthesis: A clinical study.. Clinical oral implants research. 2023. DOI: 10.1111/clr.14183.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.