Tactile sensor is useful for estimating liver hardness and liver fibrosis compared with ultrasonography and computed tomography.

Suzuki Satoshi, Watanabe Yohei, Yazawa Takashi, Ishigame Teruhide, Sassa Motoki, Monma Tomoyuki, Takawa Tadashi, Kumamoto Kensuke, Nakamura Izumi, Ohoki Shinji, Hatakeyama Yuichi, Sakuma Hiroshi, Ono Toshiyuki, Omata Sadao, Takenoshita Seiichi

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND/AIMS: We examined whether conventional ultrasonography (US) and computed tomography (CT) were useful to evaluate liver hardness and hepatic fibrosis by comparing the results with those obtained by a tactile sensor using rats with liver fibrosis.

METHODOLOGY: We used 44 Wistar rats in which liver fibrosis was induced by intraperitoneal administration of thioacetamide. The CT and US values of each liver were measured before laparotomy. After laparotomy, a tactile sensor was used to measure liver hardness. We prepared Azan stained sections of each excised liver specimen and calculated the degree of liver fibrosis (HFI: hepatic fibrosis index) by computed color image analysis.

RESULTS

The stiffness values and HFI showed a positive correlation (r=0.690, p<0.001), as did the tactile values and HFI (r=0.709, p<0.001).In addition, the stiffness and tactile values correlated positively with each other (r=0.814, p<0.001). There was no correlation between the CT values and HFI, as well as no correlation between the US values and HFI.

CONCLUSION

We confirmed that it was difficult to evaluate liver hardness and HFI by CT or US examination, and considered that, at present, a tactile sensor is useful method for evaluating HFI.

Для цитирования: Suzuki Satoshi, Watanabe Yohei, Yazawa Takashi, Ishigame Teruhide, Sassa Motoki, Monma Tomoyuki, Takawa Tadashi, Kumamoto Kensuke, Nakamura Izumi, Ohoki Shinji, Hatakeyama Yuichi, Sakuma Hiroshi, Ono Toshiyuki, Omata Sadao, Takenoshita Seiichi. Tactile sensor is useful for estimating liver hardness and liver fibrosis compared with ultrasonography and computed tomography.. Fukushima journal of medical science. 2014. DOI: 10.5387/fms.2013-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.