MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1006/jaut.2001.0540

Медицинская библиотека · Journal of autoimmunity · 2001

Thermolabile and calcium-dependent serum factor interferes with polymerized actin, and impairs anti-actin antibody detection.

Cançado E L, Abrantes-Lemos C P, Vilas-Boas L S, Novo N F, Carrilho F J, Laudanna A A

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

The detection of anti-actin (AAA) by immunofluorescence is hindered by the presence of a serum factor. To better understand how it interferes with AAA detection, we tested sera from 20 patients with autoimmune hepatitis, and from 21 healthy adults, diluted 1:10 and prepared as follows: (A) diluted with PBS; (B) inactivated at 56 degrees C, and diluted with PBS; (C) diluted with 34 mM EDTA/PBS; (D) heated and diluted with EDTA/PBS. To reveal AAA, a fluorescein-labelled anti-human IgG was used in the process of indirect immunofluorescence. In a parallel assay, the substrate, acetone-fixed human fibroblasts, was preincubated with sera prepared as if it were to identify AAA, but instead, a rhodamine-phalloidin was used to identify F-actin, by direct immunofluorescence. All sera from patients were reactive to AAA when heat-inactivated and/or calcium-chelated, and 60% of them when diluted with unmodified sera (P=0.004). F-actin continued to be present after preincubation with heat-inactivated or calcium-chelated sera from patients and healthy controls, and in 41.5% of reactions with unmodified serum (P=0.0000001). The heat inactivation and the calcium chelation were both efficient procedures for maintaining the microfilament structure intact after serum incubation and, therefore, for identifying AAA.

Для цитирования: Cançado E L, Abrantes-Lemos C P, Vilas-Boas L S, Novo N F, Carrilho F J, Laudanna A A. Thermolabile and calcium-dependent serum factor interferes with polymerized actin, and impairs anti-actin antibody detection.. Journal of autoimmunity. 2001. DOI: 10.1006/jaut.2001.0540.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.