Measuring the validity and reliability of the Apple Watch as a physical activity monitor.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Zhang Peng, Godin Steven D, Owens Matthew V
Аннотация
BACKGROUND: This study aimed to investigate the validity and reliability of the energy expenditure (EE) estimation of Apple Watch® among college students.
METHODS: Thirty college students completed two sets of three 10-minute treadmill walking and running trials while wearing three Apple watches and being connected to indirect calorimetry. The walking trials were at speeds of 54, 80, and 107 m·min-1 while the running trials were at 134, 161, 188 m·min-1. Energy expenditure comparisons were made using Two-way ANOVA with repeated measures. Reliability was analyzed by Intraclass Correlation.
RESULTS: There was no significant device x speed interactions (F (15, 696)=1.113, P=0.341) between the indirect calorimetry (criterion) and Apple Watch®. The lowest Inter-Class Correlation (ICC) scores were 0.49 (95%CI) at 54 while the highest were 0.72 (95%CI) at 107 and 134 m·min-1.
CONCLUSIONS: Apple Watch® demonstrated a low to moderate validity and reliability on measuring EE.
METHODS: Thirty college students completed two sets of three 10-minute treadmill walking and running trials while wearing three Apple watches and being connected to indirect calorimetry. The walking trials were at speeds of 54, 80, and 107 m·min-1 while the running trials were at 134, 161, 188 m·min-1. Energy expenditure comparisons were made using Two-way ANOVA with repeated measures. Reliability was analyzed by Intraclass Correlation.
RESULTS: There was no significant device x speed interactions (F (15, 696)=1.113, P=0.341) between the indirect calorimetry (criterion) and Apple Watch®. The lowest Inter-Class Correlation (ICC) scores were 0.49 (95%CI) at 54 while the highest were 0.72 (95%CI) at 107 and 134 m·min-1.
CONCLUSIONS: Apple Watch® demonstrated a low to moderate validity and reliability on measuring EE.