MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/jisppd.jisppd_446_23

Медицинская библиотека · Journal of the Indian Society of Pedodontics and Preventive Dentistry · 2024

Quantification of tongue coating using quantitative light-induced fluorescence-digital image analysis and its correlation with visual evaluation.

Shanbhog Raghavendra, Harjai Gunica, Tiwari Saisaumya, Bhojraj Nandlal

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The tongue coating is a grayish-white deposit that quickly reflects the state of health or disease of the human body. Quantitative light-induced fluorescence (QLF) is a novel digital imaging system that objectively quantifies tongue coating.

AIMS: The present study aims to evaluate the correlation between the visual assessment of tongue coating and tongue coating by analysis of QLF-digital (QLF-D) images.

SETTINGS AND

DESIGN

This was an in vivo explorative study.

MATERIALS AND

METHODS

Fifty children aged 11-13 years with clinically visible tongue coating were selected for the study. Tongue coating was assessed clinically by the Tongue Coating Index (Shimizu et al., 2007) and digitally by QLF-D Biluminator™ 2, C3 software.

STATISTICAL ANALYSIS: Data obtained were subjected to statistical analysis using SPSS 23.0 software. Spearman's rho correlation test was done, and P < 0.05 was considered statistically significant.

RESULTS

A statistically significant correlation was found between the visual assessment scoring and the QLF image analysis for the evaluation of tongue coating.

CONCLUSION

The Digital QLF tongue imaging system was found to be reliable due to its correlation with the clinical score and objective nature.

Для цитирования: Shanbhog Raghavendra, Harjai Gunica, Tiwari Saisaumya, Bhojraj Nandlal. Quantification of tongue coating using quantitative light-induced fluorescence-digital image analysis and its correlation with visual evaluation.. Journal of the Indian Society of Pedodontics and Preventive Dentistry. 2024. DOI: 10.4103/jisppd.jisppd_446_23.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.