MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.heares.2025.109375

Медицинская библиотека · Hearing research · 2025

Reaction times of cochlear implant users to a change in electrode or modulation frequency in the presence of a masker.

Noordanus E, Mens L H M, van Opstal A J

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Spatial and temporal selectivity vary substantially between cochlear implant users, resulting in large differences in speech perception. Direct electrode stimulation offers precise control to capture this variability. However, most studies using direct stimulation have not incorporated interfering stimuli, which may not reflect the complex nature of speech and ambient noise. To address this gap, we introduce the Electrode Interaction Reaction Time (ELI-RT) paradigm, which uses amplitude-modulated, interleaved pulses on two closely spaced electrodes at clinical pulse rates. ELI-RT includes two test types: "∆EL", measuring the participants' manual reaction times to a change in stimulated electrode, and "∆MF", measuring reaction times to a modulation frequency change. Both tests include ongoing interference on an adjacent electrode. We also measured speech-in-noise recognition thresholds. We analyzed data from 16 unilateral cochlear implant users and found that ELI-RT could dissociate participant-, electrode-, and test-dependent factors. The effect of the electrode location along the array differed considerably between participants. The ∆EL and ∆MF tests provided partly complementary insights. Reaction times on these tests correlated with speech-in-noise perception, especially for changes that typically yielded shorter reaction times and for electrodes located in the middle of the array. In conclusion, reaction times to changes in the place of stimulation and modulation frequency, in the presence of interference from an adjacent electrode, offer detailed insights into the acuity of information transfer along the cochlear implant electrode array to the central auditory pathways in cochlear implant users.

Для цитирования: Noordanus E, Mens L H M, van Opstal A J. Reaction times of cochlear implant users to a change in electrode or modulation frequency in the presence of a masker.. Hearing research. 2025. DOI: 10.1016/j.heares.2025.109375.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.