Influence of parameter settings in voxel-based morphometry 8. Using DARTEL and region-of-interest on reproducibility in gray matter volumetry.

Goto M, Abe O, Aoki S, Hayashi N, Miyati T, Takao H, Matsuda H, Yamashita F, Iwatsubo T, Mori H, Kunimatsu A, Ino K, Yano K, Ohtomo K, Japanese Alzheimer’s Disease Neuroimaging Initiative

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

To investigate whether reproducibility of gray matter volumetry is influenced by parameter settings for VBM 8 using Diffeomorphic Anatomical Registration Through Exponentiated Lie Algebra (DARTEL) with region-of-interest (ROI) analyses.

METHODS

We prepared three-dimensional T1-weighted magnetic resonance images (3D-T1WIs) of 21 healthy subjects. All subjects were imaged with each of five MRI systems. Voxel-based morphometry 8 (VBM 8) and WFU PickAtlas software were used for gray matter volumetry. The bilateral ROI labels used were those provided as default settings with the software: Frontal Lobe, Hippocampus, Occipital Lobe, Orbital Gyrus, Parietal Lobe, Putamen, and Temporal Lobe. All 3D-T1WIs were segmented to gray matter with six parameters of VBM 8, with each parameter having between three and eight selectable levels. Reproducibility was evaluated as the standard deviation (mm³) of measured values for the five MRI systems.

RESULTS

Reproducibility was influenced by 'Bias regularization (BiasR)', 'Bias FWHM', and 'De-noising filter' settings, but not by 'MRF weighting', 'Sampling distance', or 'Warping regularization' settings. Reproducibility in BiasR was influenced by ROI. Superior reproducibility was observed in Frontal Lobe with the BiasR1 setting, and in Hippocampus, Parietal Lobe, and Putamen with the BiasR3*, BiasR1, and BiasR5 settings, respectively.

CONCLUSION

Reproducibility of gray matter volumetry was influenced by parameter settings in VBM 8 using DARTEL and ROI. In multi-center studies, the use of appropriate settings in VBM 8 with DARTEL results in reduced scanner effect.

Для цитирования: Goto M, Abe O, Aoki S, Hayashi N, Miyati T, Takao H, Matsuda H, Yamashita F, Iwatsubo T, Mori H, Kunimatsu A, Ino K, Yano K, Ohtomo K, Japanese Alzheimer’s Disease Neuroimaging Initiative. Influence of parameter settings in voxel-based morphometry 8. Using DARTEL and region-of-interest on reproducibility in gray matter volumetry.. Methods of information in medicine. 2014. DOI: 10.3414/me14-01-0049.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.