Barakat Monique T, Liman Andrew, Gugig Roberto
Аннотация
BACKGROUND AND AIMS: Duodenoscopes with single-use end caps were introduced to minimize infection risk, but they are unstudied in pediatrics.
METHODS: We collected clinical data and endoscopists' evaluations of duodenoscopes with single-use end caps versus reusable duodenoscopes over 18 months.
RESULTS: A total of 106 ERCPs were performed for patients aged 1 to 18 (mean, 14.2) years. Forty-six involved single-use end caps, with 9 requiring crossover to reusable duodenoscopes. ERCPs involving single-use end caps resulted in more instances of mucosal trauma (10 vs 0; P < .05) and post-ERCP pancreatitis (4 vs 1; P < .05) and accounted for 8 of 9 ERCPs requiring advanced cannulation techniques. No post-ERCP infections occurred. Reported challenges included single-use end cap stiffness and difficulty with their alignment for cannulation.
CONCLUSIONS: We report difficulty with advancement, greater reliance on advanced cannulation techniques, and higher rates of post-ERCP pancreatitis when using duodenoscopes with single-use end caps in pediatric ERCP. This area warrants further study.
METHODS: We collected clinical data and endoscopists' evaluations of duodenoscopes with single-use end caps versus reusable duodenoscopes over 18 months.
RESULTS: A total of 106 ERCPs were performed for patients aged 1 to 18 (mean, 14.2) years. Forty-six involved single-use end caps, with 9 requiring crossover to reusable duodenoscopes. ERCPs involving single-use end caps resulted in more instances of mucosal trauma (10 vs 0; P < .05) and post-ERCP pancreatitis (4 vs 1; P < .05) and accounted for 8 of 9 ERCPs requiring advanced cannulation techniques. No post-ERCP infections occurred. Reported challenges included single-use end cap stiffness and difficulty with their alignment for cannulation.
CONCLUSIONS: We report difficulty with advancement, greater reliance on advanced cannulation techniques, and higher rates of post-ERCP pancreatitis when using duodenoscopes with single-use end caps in pediatric ERCP. This area warrants further study.