MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2003

MIRD Pamphlet No 19: absorbed fractions and radionuclide S values for six age-dependent multiregion models of the kidney.

Bouchet Lionel G, Bolch Wesley E, Blanco H Pablo, Wessels Barry W, Siegel Jeffry A, Rajon Didier A, Clairand Isabelle, Sgouros George

Сравнительное исследованиеОценочное исследованиеСтатьяПоддержка правительства СШАПеревод пока не подготовлен

Аннотация

UNLABELLED: As one of the major organs of the excretory pathway, the kidneys represent a frequent source of radiopharmaceutical uptake in both diagnostic and therapeutic nuclear medicine. The unique organization of the functional tissues of the organ ensures transient changes in suborgan localization of renal activity. Current single-region dosimetric models of the kidneys, however, force the assumption of a uniform distribution of radioactivity across the entire organ. The average absorbed dose to the kidneys predicted by such models can misrepresent local regional doses to specific substructures.

METHODS

To facilitate suborgan dosimetry for the kidneys, 6 new age-dependent multiregion kidney models are presented. The outer dimensions of the models conform to those used currently in single-region kidney models, whereas interior structures are defined for the renal cortex, the medullary pyramids with papillae (2 vertical and 3 horizontal), and the renal pelvis. Absorbed fractions of energy were calculated for both photon and electron sources (10 keV to 4 MeV) located in each source region within the 6 age-dependent models. The absorbed fractions were then used to assemble S values for radionuclides of potential interest in suborgan kidney dosimetry.

RESULTS

For the adult, the absorbed dose to the renal cortex for (90)Y-labeled compounds retained within that subregion is approximately 1.3 times that predicted by the single-region kidney model, whereas the medullary dose is only 26% of that same single-region value. For compounds that are rapidly filtered in the kidneys, the renal cortex dose is approximately one-half of that predicted under the single-region model, whereas the tissues of the medullary pyramids receive an absorbed dose 1.5-1.8 times larger.

CONCLUSION

The multiregion model described here permits estimates of regional kidney dose not previously supported by current single-region models. Full utilization of the new model, however, requires serial imaging of the kidneys with regions of interest assigned to the renal cortex and medulla.

Для цитирования: Bouchet Lionel G, Bolch Wesley E, Blanco H Pablo, Wessels Barry W, Siegel Jeffry A, Rajon Didier A, Clairand Isabelle, Sgouros George. MIRD Pamphlet No 19: absorbed fractions and radionuclide S values for six age-dependent multiregion models of the kidney.. Journal of nuclear medicine : official publication, Society of Nuclear Medicine. 2003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.