Crohn's disease: factors associated with exposure to high levels of diagnostic radiation.

Desmond A N, O'Regan K, Curran C, McWilliams S, Fitzgerald T, Maher M M, Shanahan F

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

AIMS: Exposure to diagnostic radiation may be associated with increased risk of malignancy. The aims of this study were to (1) examine patterns of use of imaging in Crohn's disease; (2) quantify the cumulative effective dose (CED) of diagnostic radiation received by patients; and (3) identify patients at greatest risk of exposure to high levels of diagnostic radiation.

METHODS

409 patients with Crohn's disease were identified at a tertiary centre. CED was calculated retrospectively from imaging performed between July 1992 and June 2007. High exposure was defined as CED>75 mSv, an exposure level which has been reported to increase cancer mortality by 7.3%. Complete data were available for 399 patients. 45 were excluded (20 attended outside the study period, 25 were primarily managed at other centres).

RESULTS

Use of computed tomography increased significantly and accounted for 77.2% of diagnostic radiation. Mean CED was 36.1 mSv and exceeded 75 mSv in 15.5% of patients. Factors associated with high cumulative exposure were: age <17 years at diagnosis (hazard ratio 2.1, confidence interval (CI) 1.1 to 4.1), upper gastrointestinal tract disease (odds ratio (OR) 2.4, CI 1.2 to 4.9), penetrating disease (OR 2.0, CI 1.0 to 3.9) and requirement for intravenous steroids (OR 3.7, CI 2.0 to 6.6); infliximab (OR 2.3, CI 1.2 to 4.4); or multiple (>1) surgeries (OR 2.7, CI 1.4 to 5.4).

CONCLUSIONS

Identifiable subsets of patients with Crohn's disease are at risk of exposure to significant amounts of diagnostic radiation. Given the background risk of neoplasia and exposure to potentially synergistic agents such as purine analogues and other immune modulators, specialist centres should develop low-radiation imaging protocols.

Для цитирования: Desmond A N, O'Regan K, Curran C, McWilliams S, Fitzgerald T, Maher M M, Shanahan F. Crohn's disease: factors associated with exposure to high levels of diagnostic radiation.. Gut. 2008. DOI: 10.1136/gut.2008.151415.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.