BACKGROUND

Proximal lung tumors, though not discernable by means of transthoracic ultrasound (US), may cause varying degrees of pulmonary collapse and postobstructive pneumonitis which may give rise to a 'drowned lung' appearance on chest computed tomography (CT) and US. The diagnostic yield for malignancy of US-assisted transthoracic fine-needle aspiration (FNA) of these areas of drowned lung is unknown.

OBJECTIVES

We aimed to explore the feasibility of US-assisted FNA in this setting by prospectively investigating its diagnostic yield and safety.

METHODS

We enrolled 31 patients (aged 59.4 ± 9.7 years, 17 males) with central tumors and secondary drowned lung on CT scan. A respiratory physician performed transthoracic US to identify the target drowned lung tissue. Three US-assisted superficial FNA passes (≤20 mm from the pleura) were followed by 3 deeper FNA passes (>20 mm) aimed in the direction of a visible or approximated central mass. Rapid on-site evaluation of specimens was used.

RESULTS

Superficial FNA was diagnostic in 11 patients (35.5%), whereas deeper FNA was diagnostic in 23 patients (74.2%, p = 0.002). Deeper FNA confirmed malignancy in all cases with diagnostic superficial FNA. We observed no pneumothoraces or major hemorrhage. All patients were ultimately diagnosed with malignancy (bronchogenic carcinoma, n = 30; lymphoma, n = 1).

CONCLUSIONS

US-assisted FNA of drowned lung has an acceptable diagnostic yield and is safe.

Для цитирования: Koegelenberg Coenraad F N, Bolliger Chris T, Irusen Elvis M, Wright Colleen A, Louw Mercia, Schubert Pawel T, Diacon Andreas H. The diagnostic yield and safety of ultrasound-assisted transthoracic fine-needle aspiration of drowned lung.. Respiration; international review of thoracic diseases. 2010. DOI: 10.1159/000319576.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.