MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcrs.2006.09.020

Медицинская библиотека · Journal of cataract and refractive surgery · 2007

Synchrony dual-optic accommodating intraocular lens. Part 1: optical and biomechanical principles and design considerations.

McLeod Stephen D, Vargas Luis G, Portney Val, Ting Albert

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To describe a dual-optic accommodating intraocular lens (IOL) based on theoretical considerations.

SETTING

University and independent research group.

METHODS

Ray-tracing analysis using optical modeling software (ZEMAXTM, Focus Software Inc., Tucson, Ariz) in a theoretical model eye was used to analyze lens configurations to optimize the accommodative and magnification effects of axial lens displacement. Finite-element modelling using a commercially available PC-based software package (COSMOS DesignSTAR) was applied to design the biomechanical parameters of the inter-optic articulations and optics.

RESULTS

Ray-tracing analysis indicated that a dual-optic design with a high plus-powered front optic coupled to a minus posterior optic produced greater change in conjugation power of the eye compared to a single-optic intraocular lens and that magnification effects were unlikely to account for improved near vision. Finite-element modelling indicated that the 2 optics can be linked by spring-loaded haptics that allow anterior and posterior axial displacement of the front optic in response to changes in ciliary body tone and capsular tension.

CONCLUSION

A dual-optic design linked by spring haptics increases the accommodative effect of axial optic displacement with minimal magnification effect and has promise for improving the performance of accommodative intraocular lenses.

Для цитирования: McLeod Stephen D, Vargas Luis G, Portney Val, Ting Albert. Synchrony dual-optic accommodating intraocular lens. Part 1: optical and biomechanical principles and design considerations.. Journal of cataract and refractive surgery. 2007. DOI: 10.1016/j.jcrs.2006.09.020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.