m+Medelevator.RU
← Поиск публикаций
Fertility and sterility · 2015

Mapping of bowel occult microscopic endometriosis implants surrounding deep endometriosis nodules infiltrating the bowel.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Badescu Alexandra, Roman Horace, Aziz Moutaz, Puscasiu Lucian, Molnar Claudiu, Huet Emmanuel, Sabourin Jean-Christophe, Stolnicu Simona

Аннотация

OBJECTIVE: To provide a mapping of bowel occult microscopic endometriosis implants from colorectal specimens removed from patients who had undergone colorectal resection for deep endometriosis infiltrating the rectum.

DESIGN: A series of consecutive patients with deep endometriosis infiltrating the rectum or/and sigmoid colon, between January 2013 and December 2013.

SETTING: University tertiary referral center.

PATIENT(S): Twenty-six patients with deep endometriosis infiltrating the rectum or/and sigmoid colon.

INTERVENTION(S): Surgical management by colorectal resection.

MAIN OUTCOME MEASURE(S): Twenty-six patients with prospective recording of data (age, clinical history, symptoms, preoperative assessment, and intraoperative findings) underwent colorectal resection for bowel endometriosis. Mapping of occult microscopic endometriosis implants from specimens was established by histologic examination of 1,051 microsection slides taken from transversal macrosections of 3-mm thickness (40 microsections per patient on average).

RESULT(S): The mean (SD) length of colorectal specimens was 110 (42) mm. Microimplants were found at varying distances up to 54 mm from macronodule limits. Multiple macroscopic nodules were identified in five patients (19.2%). In 18 specimens (69%) diffusion of endometriosis microimplants was longitudinal, whereas in 8 specimens (31%) diffusion was concentrated around the macroscopic nodule. Respectively, 31%, 19%, 8%, and 4% of patients presented with endometriosis microimplants at 2, 3, 4, and 5 cm from macroscopic nodules.

CONCLUSION(S): The present data suggest that in patients presenting with deep colorectal endometriosis, microscopically complete excision of rectal endometriosis may be unachievable because of bowel occult microscopic endometriosis implants located far from macroscopic nodules.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты