OBJECTIVE

The objective of this study was to investigate the effectiveness of testing for active matrix metalloproteinase-8 (aMMP-8) by a quantitative point-of-care (PoC), chairside lateral flow immunotest and azurocidin, in the peri-implant sulcular fluid (PISF), as biomarkers for the presence or absence of peri-implant diseases.

BACKGROUND

Current research indicates that proinflammatory cytokines and extracellular matrix-degrading enzymes may be of value to diagnose and predict peri-implant disease initiation and progression, but more data are needed.

METHODS

Eighty patients with implants were recruited. PISF samples were collected and quantitatively analyzed for aMMP-8 (chairside) and azurocidin with ELISA. Radiographic assessments and clinical indices (probing depth, probing attachment level, bleeding on probing, and plaque) were recorded after sampling. Kruskal-Wallis test and pairwise post hoc Dunn-Bonferroni test were used to relate aMMP-8 levels and azurocidin levels to clinical parameters. The diagnostic ability of aMMP-8 (ng/mL) and azurocidin was analyzed by receiver operator curve analysis. Area under the curve (AUC) was calculated and the Spearman's rho, and the coefficient of determination (R2) were used to calculate the correlations between aMMP-8, azurocidin, and periodontal parameters.

RESULTS

Statistically significant differences were observed for aMMP-8 levels but not for azurocidin between healthy implants, implants with mucositis, and those with peri-implantitis (13.65 ± 7.18, 32.33 ± 21.20, and 73.07 ± 43.93 ng/mL, respectively), (Kruskall-Wallis test p < .05). The aMMP-8 test with a threshold of 20 ng/mL has a sensitivity of 71.7% and a specificity of 77.8% to identify peri-implantitis and healthy implants, respectively. AUC was found to be 0.814, and the accuracy of the method reaches 73.8%. Above a cutoff value of 33.7 ng/mL of aMMP-8, the accuracy of the test to detect peri-implantitis reaches 77.5% in relation to 62.5% of BoP from the same site.

CONCLUSION

Taken collectively, present data indicate that the aMMP-8 PoC lateral flow immunotest can be a beneficial, adjunctive diagnostic quantitative tool for real-time screening for peri-implant diseases.

Для цитирования: Xanthopoulou Vithleem, Räisänen Ismo T, Sorsa Timo, Tortopidis Dimitrios, Sakellari Dimitra. Diagnostic value of aMMP-8 and azurocidin in peri-implant sulcular fluid as biomarkers of peri-implant health or disease.. Clinical and experimental dental research. 2024. DOI: 10.1002/cre2.883.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.