Comparison of Radiation Dose and Image Quality in Pediatric Abdominopelvic Photon-Counting Versus Energy-Integrating Detector CT.

Siegel Marilyn J, Thomas Matthew Allan, Haq Adeel, Seymore Noah, Sodhi Kushaljit Singh, Abadia Andres

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVE

Adoption of abdominal photon counting detector CT (PCD-CT) into clinical pediatric CT practice requires evidence that it provides diagnostic images at acceptable radiation doses. Thus, this study aimed to compare radiation dose and image quality of PCD-CT and conventional energy-integrating detector CT (EID-CT) in pediatric abdominopelvic CT.

MATERIALS AND

METHODS

This institutional review board-approved retrospective study included 147 children (median age 8.5 y; 80 boys, 67 girls) who underwent clinically indicated contrast-enhanced abdominopelvic PCD-CT between October 1, 2022 and April 30, 2023 and 147 children (median age 8.5 y; 74 boys, 73 girls) who underwent EID-CT between July 1, 2021 and January 1, 2022. Patients in the 2 groups were matched by age and effective diameter. Radiation dose parameters (CT dose index volume, CTDI vol ; dose length product, DLP; size-specific dose estimate, SSDE) were recorded. In a subset of 25 matched pairs, subjective image quality was assessed on a scale of 1 to 4 (1=highest quality), and liver attenuation, dose-normalized noise, and contrast-to-noise ratio (CNR) were measured. Groups were compared using parametric and/or nonparametric testing.

RESULTS

Among the 147 matched pairs, there were no significant differences in sex ( P =0.576), age ( P =0.084), or diameter ( P =0.668). PCD-CT showed significantly lower median CTDI vol , DLP, and SSDE (1.6 mGy, 63.8 mGy-cm, 3.1 mGy) compared with EID-CT (3.7 mGy, 155.3 mGy-cm, 6.0 mGy) ( P< 0.001). In the subset of 25 patients, PCD-CT and EID-CT showed no significant difference in overall image quality for reader 1 (1.0 vs. 1.0, P =0.781) or reader 2 (1.0 vs. 1.0, P =0.817), or artifacts for reader 1 (1.0 vs. 1.0, P =0.688) or reader 2 (1.0 vs. 1.0, P =0.219). After normalizing for radiation dose, image noise was significantly lower with PCD-CT ( P <0.001), while CNR in the liver ( P =0.244) and portal vein ( P =0.079) were comparable to EID-CT.

CONCLUSION

Abdominopelvic PCD-CT in children significantly reduces radiation dose while maintaining subjective image quality, and accounting for dose levels, has the potential to lower image noise and achieve comparable CNR to EID-CT. These data expand understanding of the capabilities of PCD-CT and support its routine use in children.

Для цитирования: Siegel Marilyn J, Thomas Matthew Allan, Haq Adeel, Seymore Noah, Sodhi Kushaljit Singh, Abadia Andres. Comparison of Radiation Dose and Image Quality in Pediatric Abdominopelvic Photon-Counting Versus Energy-Integrating Detector CT.. Journal of computer assisted tomography. 2025. DOI: 10.1097/rct.0000000000001730.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.