MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2319/080616-603.1

Медицинская библиотека · The Angle orthodontist · 2017

Herbst appliance effects on pharyngeal airway ventilation evaluated using computational fluid dynamics.

Iwasaki Tomonori, Sato Hideo, Suga Hokuto, Minami Ayaka, Yamamoto Yuushi, Takemoto Yoshihiko, Inada Emi, Saitoh Issei, Kakuno Eriko, Kanomi Ryuzo, Yamasaki Youichi

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate the effect of a Herbst appliance on ventilation of the pharyngeal airway (PA) using computational fluid dynamics (CFD).

MATERIALS AND

METHODS

Twenty-one Class II patients (10 boys; mean age, 11.7 years) who required Herbst therapy with edgewise treatment underwent cone-beam computed tomography (CBCT) before and after treatment. Nineteen Class I control patients (8 boys; mean age, 11.9 years) received edgewise treatment alone. The pressure and velocity of the PA were compared between the groups using CFD based on three-dimensional CBCT images of the PA.

RESULTS

The change in oropharyngeal airway velocity in the Herbst group (1.95 m/s) was significantly larger than that in the control group (0.67 m/s). Similarly, the decrease in laryngopharyngeal airway velocity in the Herbst group (1.37 m/s) was significantly larger than that in the control group (0.57 m/s).

CONCLUSION

The Herbst appliance improves ventilation of the oropharyngeal and laryngopharyngeal airways. These results may provide a useful assessment of obstructive sleep apnea treatment during growth.

Для цитирования: Iwasaki Tomonori, Sato Hideo, Suga Hokuto, Minami Ayaka, Yamamoto Yuushi, Takemoto Yoshihiko, Inada Emi, Saitoh Issei, Kakuno Eriko, Kanomi Ryuzo, Yamasaki Youichi. Herbst appliance effects on pharyngeal airway ventilation evaluated using computational fluid dynamics.. The Angle orthodontist. 2017. DOI: 10.2319/080616-603.1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.