MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00056-016-0051-3

Медицинская библиотека · Journal of orofacial orthopedics = Fortschritte der Kieferorthopadie : Organ/official journal Deutsche Gesellschaft fur Kieferorthopadie · 2016

Patient survey on Invisalign® treatment comparing [corrected] the SmartTrack® material to the previously used [corrected] aligner material.

Bräscher Anne-Kathrin, Zuran Dietmar, Feldmann Robert E, Benrath Justus

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

In 2013, a novel material SmartTrack® was introduced to replace the previous material used for Invisalign® aligners. We conducted this study to test how this transition was accepted by patients during ongoing Invisalign® treatment.

METHODS

We surveyed a total of 72 patients (68 % women, 32 % men, mean age: 29.3 ± 9.2 years) who had worn the new material for a mean of 6 months. They completed a questionnaire with 25 items that compared both materials in terms of pain, pressure upon insertion, comfort, mucosal irritation, phonetics, discoloration, and taste.

RESULTS

On a numerical rating scale (NRS) ranging from 0 to 10, the new aligner material was rated by the respondents to cause significantly (p < 0.001) less maximum pain than the old material (2.8 vs. 3.8). Significant reductions were obtained for duration of pain (p < 0.001) and duration of pressure (2.5 vs. 1.9 days; p = 0.001) upon insertion of the aligners. Over 90 % of the respondents indicated less or equal pain during eating, felt that the new material offered a tighter fit, and provided more favorable ratings for impairment, durability, and discoloration. Improved comfort was reported by 50 % of the respondents.

CONCLUSIONS

The new material was favorably rated by the patients and showed significant reductions in pain intensity, pain duration, and pressure upon insertion. Important clinical parameters like overall comfort and impairment also were improved. The clinical effectiveness of the new material remains to be investigated.

Для цитирования: Bräscher Anne-Kathrin, Zuran Dietmar, Feldmann Robert E, Benrath Justus. Patient survey on Invisalign® treatment comparing [corrected] the SmartTrack® material to the previously used [corrected] aligner material.. Journal of orofacial orthopedics = Fortschritte der Kieferorthopadie : Organ/official journal Deutsche Gesellschaft fur Kieferorthopadie. 2016. DOI: 10.1007/s00056-016-0051-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.