m+Medelevator.RU
← Поиск публикаций
Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology · 2020

Single-fraction prostate stereotactic body radiotherapy: Dose reconstruction with electromagnetic intrafraction motion tracking.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Jaccard Maud, Ehrbar Stefanie, Miralbell Raymond, Hagen Tobias, Koutsouvelis Nikolaos, Poulsen Per, Rouzaud Michel, Tanadini-Lang Stephanie, Tsoutsou Pelagia, Guckenberger Matthias, Zilli Thomas

Аннотация

PURPOSE: To reconstruct the dose delivered during single-fraction urethra-sparing prostate stereotactic body radiotherapy (SBRT) accounting for intrafraction motion monitored by intraprostatic electromagnetic transponders (EMT).

METHODS: We analyzed data of 15 patients included in the phase I/II "ONE SHOT" trial and treated with a single fraction of 19 Gy to the planning target volume (PTV) and 17 Gy to the urethra planning risk volume. During delivery, prostate motion was tracked with implanted EMT. SBRT was interrupted when a 3-mm threshold was trespassed and corrected unless the offset was transient. Motion-encoded reconstructed (MER) plans were obtained by splitting the original plans into multiple sub-beams with isocenter shifts based on recorded EMT positions, mimicking prostate motion during treatment. We analyzed intrafraction motion and compared MER to planned doses.

RESULTS: The median EMT motion range (±SD) during delivery was 0.26 ± 0.09, 0.22 ± 0.14 and 0.18 ± 0.10 cm in the antero-posterior, supero-inferior, and left-right axes, respectively. Treatment interruptions were needed for 8 patients because of target motion beyond limits in the antero-posterior (n = 6) and/or supero-inferior directions (n = 4). Comparing MER vs. original plan there was a median relative dose difference of -1.9% (range, -7.9 to -1.0%) and of +0.5% (-0.3-1.7%) for PTV D98% and D2%, respectively. The clinical target volume remained sufficiently covered with a median D98% difference of -0.3% (-1.6-0.5%). Bladder and rectum dosimetric parameters showed significant differences between original and MER plans, but mostly remained within acceptable limits.

CONCLUSIONS: The dosimetric impact of intrafraction prostate motion was minimal for target coverage for single-fraction prostate SBRT with real-time electromagnetic tracking combined with beam gating.