MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.urology.2024.01.004

Медицинская библиотека · Urology · 2024

Validation of Urostomy Parastomal Herniation Incisional Prevention Strategies.

Kanabolo Diboro L, Maxwell Adam D, Kumar Yashwanth Nanda, Schade George R

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate simulated parastomal herniation forces in in vitro abdominal fascial models. Our group previously illustrated how incision type may play a consequential role in bowel herniation force generated across an incision using several abdominal fascia models. We sought to (1) Confirm findings in fresh human tissue, (2) Assess correlation between herniation force and incision size, and (3) Determine whether incision type impacts drainage in a simulated ex vivo ileal conduit.

MATERIALS AND

METHODS

Axial tension force (N) of herniation was measured using our previously published protocol, pulling a Foley catheter balloon 3.8 cm diameter affixed to a dynamometer through silicone/fascial incisions ranging 3-5.8 cm. We simulated ileal conduits using bovine small intestine with stoma matured through human fascia using 3.0 cm linear or cruciate incisions. The conduit's caudal end was catheterized and filled at 20 mL/min. Drainage was measured by pad weight change. Two-sided α < 0.05 was used to reject the null hypothesis.

RESULTS

Mean (±SD) herniation forces in fresh human fascia varied significantly across linear longitudinal, linear transverse, and cruciate incisions (20.9 ± 3.7, 23.3 ± 8.8, and 8.9 ± 3.8 N, respectively [P = .011]). Fresh human fascial linear incisions 3 cm in diameter had a herniation force of 22.1 ± 6.3 vs 3.5 ± 0.7 N for 5.8 cm incisions when herniating a 3.8 cm balloon (P = .002). All observations were similar in silicone. In simulated ileal conduit, mean drainage: 70.8 ± 3.6 vs 82.1 ± 9.7 mL (linear vs cruciate) after 100 mL instilled, respectively (P = .05).

CONCLUSION

This ex vivo study further suggests incision type has predictable influence on herniation force. These data support standardization of urostomy construction techniques and evaluating the clinical impact of stomal maturation techniques on parastomal hernia rates.

Для цитирования: Kanabolo Diboro L, Maxwell Adam D, Kumar Yashwanth Nanda, Schade George R. Validation of Urostomy Parastomal Herniation Incisional Prevention Strategies.. Urology. 2024. DOI: 10.1016/j.urology.2024.01.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.