Systematic review of the diagnostic accuracy of 201Tl single photon emission computed tomography in the detection of recurrent glioma.

Vos Maaike J, Tony Ban N, Hoekstra Otto S, Postma Tjeerd J, Heimans Jan J, Hooft Lotty

СтатьяСистематический обзорПеревод пока не подготовлен

Аннотация

OBJECTIVE

To determine the diagnostic accuracy of 201Tl SPECT in the detection of tumour recurrence in patients with previous radiotherapy for supratentorial glioma.

METHODS

The databases of PubMed and Embase were searched for relevant studies. Two reviewers independently selected and extracted data on study characteristics, quality and accuracy of studies. Studies were included if they comprised at least six eligible patients who underwent 201Tl SPECT (index test) and in whom (histo)pathological confirmation (reference test) of the suspected brain lesion was obtained. Because of the methodological and statistical heterogeneity of the included studies, a quantitative meta-analysis was not performed. Instead, for every individual study, the sensitivity, specificity and diagnostic odds ratio of 201Tl SPECT was calculated.

RESULTS

Eight studies met the inclusion criteria. Only one was considered of high methodological quality. Methodological limitations referred most notably to blinding and patient selection. The diagnostic odds ratio was greater than 1 in all studies included, with a broad range (2-351), and relatively wide 95% confidence intervals. The sensitivity of 201Tl SPECT ranged from 0.43 to 1.00, and the specificity from 0.25 to 1.00.

CONCLUSION

201Tl SPECT seems a valuable method in the detection of tumour recurrence in patients treated with radiotherapy for supratentorial glioma. However, the evidence is not very robust because of the low quality and high heterogeneity of the studies included. Future studies are warranted to further explore the diagnostic potential of 201Tl SPECT, and to determine optimum thresholds for the detection of glioma recurrence.

Для цитирования: Vos Maaike J, Tony Ban N, Hoekstra Otto S, Postma Tjeerd J, Heimans Jan J, Hooft Lotty. Systematic review of the diagnostic accuracy of 201Tl single photon emission computed tomography in the detection of recurrent glioma.. Nuclear medicine communications. 2007. DOI: 10.1097/mnm.0b013e328155d131.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.