MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/0310057x1003800110

Медицинская библиотека · Anaesthesia and intensive care · 2010

Fibreoptic assessment of paediatric sized laryngeal mask airways.

Von Ungern-Sternberg B S, Wallace C J, Sticks S, Erb T O, Chambers N A

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Laryngeal mask airways (LMA) are commonly used in paediatric anaesthesia. A well-placed LMA should provide a direct view of the vocal cords facilitating bronchoscopy or fibreoptic intubation. The aim of this audit was to assess the bronchoscopic view of the glottis obtained through an LMA with regard to its size. We prospectively assessed the position of LMAs in relation to the glottic aperture in 350 children (zero to seven years) undergoing elective fibreoptic examination of the upper and/or lower airways. Following induction of anaesthesia and positioning of the LMA, a fibreoptic evaluation of the view of the glottis was performed (complete, partial or no visualisation). Chest movement on manual ventilation was judged as good in the majority of patients and adequate for the remainder. No overt signs of airway obstruction were noted in any patient. However, a complete view of the glottic aperture was present in only 50% of size 1 LMAs, 57.5% of size 1.5, 72.7% of size 2 and 77.8% of size 2.5. The epiglottis impinged on the LMA opening, partially obstructing the view of the glottis in 36.3% of size 1 LMAs, 31.5% of size 1.5, 21% of size 2 and 17.8% of size 2.5. In 13.7% of size 1 LMAs, 11% of size 1.5, 6.3% of size 2 and 4.4% of size 2.5, the epiglottis was completely downfolded, obstructing the view of the glottic aperture. The findings indicate that even if ventilation is judged as adequate, smaller paediatric LMAs are more commonly associated with suboptimal anatomical positioning with partial obstruction of the glottic aperture than larger LMAs, and therefore may require repositioning more often.

Для цитирования: Von Ungern-Sternberg B S, Wallace C J, Sticks S, Erb T O, Chambers N A. Fibreoptic assessment of paediatric sized laryngeal mask airways.. Anaesthesia and intensive care. 2010. DOI: 10.1177/0310057x1003800110.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.