Automated detection and measurement of uterine peristalsis in cine MR images.

Watanabe Koichi, Kataoka Masako, Yano Kojiro, Nishio Shuro, Umehana Masaki, Kido Aki, Togashi Kaori

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the ability of automated software to quantify uterine peristalsis on cine magnetic resonance imaging (MRI).

MATERIALS AND

METHODS

At 1.5T, half-Fourier acquisition single-shot turbo spin echo (HASTE) techniques were used to obtain 60 serial images over 3 minutes (TR/TE 3000/80 msec) in a midsagittal plane of the uterus. Thirty-two cine MR datasets, obtained from 16 healthy females, were analyzed. Uterine peristalsis was defined as the traveling waves of decreasing signal intensity on the endometrium-junctional zone border. The software detected traveling waves by identifying the neighboring areas showing similar patterns of signal intensity decrease in a different timing. Quantification of uterine peristaltic wave using the fully automated software was compared to qualitative visual evaluation by two readers.

RESULTS

The mean number (and standard deviation) of peristaltic waves detected by the fully automated software and visual evaluations (readers 1 and 2) were 5.4 (3.0), 4.7 (3.1), and 4.5 (3.1) per 3 minutes, respectively. Quantification by fully automated software demonstrated excellent agreement with repeated measurement (weighted kappa 0.99) and with qualitative visual evaluations (range 0.89-0.95), comparable to interreader agreement by visual evaluations (range 0.89-0.93).

CONCLUSION

The fully automated software can be used to quantify uterine peristalsis comparable to visual evaluation.

Для цитирования: Watanabe Koichi, Kataoka Masako, Yano Kojiro, Nishio Shuro, Umehana Masaki, Kido Aki, Togashi Kaori. Automated detection and measurement of uterine peristalsis in cine MR images.. Journal of magnetic resonance imaging : JMRI. 2014. DOI: 10.1002/jmri.24817.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.