MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1017/s0022215122001025

Медицинская библиотека · The Journal of laryngology and otology · 2022

Laryngeal injury in a coronavirus disease 2019 caregiver following voluntary cough-holding within an inappropriately sized personal protective equipment suit.

Dutta M, Raghu G

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To document laryngeal framework rupture following voluntary cough-holding as an airway complication of donning a personal protective equipment suit that was too small in size.

METHODS

Clinical record and literature review, with proposition of plausible aerodynamics of the airway injury.

RESULTS

Whilst carrying out his duty in the coronavirus disease ward, a resident attempted to stifle a paroxysm of cough when wearing a personal protective equipment suit that was too small with his neck flexed and restricted. There was a sudden release of pressure, intense pain and swelling in the neck with crepitus. Imaging revealed a non-displaced fracture in the lower end of the partially ossified right thyroid lamina, a cricothyroid membrane tear and subcutaneous emphysema. The symptoms resolved gradually on conservative management.

CONCLUSION

This report underlines the importance of donning appropriately sized personal protective equipment and encouraging its proper use amongst coronavirus disease 2019 caregivers. Non-traumatic laryngeal injury, itself a rare event, has never been reported as a posture-related complication of wearing personal protective equipment.

Для цитирования: Dutta M, Raghu G. Laryngeal injury in a coronavirus disease 2019 caregiver following voluntary cough-holding within an inappropriately sized personal protective equipment suit.. The Journal of laryngology and otology. 2022. DOI: 10.1017/s0022215122001025.