MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/bio.1170100408

Медицинская библиотека · Journal of bioluminescence and chemiluminescence · 1995

Comparison of seven bio- and chemiluminescent reagents for in situ detection of antigens and nucleic acids.

Lamarcq L, Lorimier P, Negoescu A, Labat-Moleur F, Durrant I, Brambilla E

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Bio- and chemiluminescence have proved sensitive enough to compete with chromogenic and radioisotopic tracers for in situ detection. However, they must also provide a discriminant morphological analysis of the specific signal. We have tested seven bio- or chemiluminescent reagents for tissue antigen and nucleic acid detection by immunocytochemistry (ICC) or in situ hybridization (ISH). They were based on luminescent detection of peroxidase, alkaline phosphatase, beta-galactosidase or xanthine oxidase. We also explored whether high molecular weight polymers could increase the spatial definition of the photon emission. An ICCD camera was used to collect the light signal provided by immunolabelling of endothelial cells and by ISH of human papilloma virus on cell smears. Among the enzyme-luminescent substrate combinations tested, the enhanced luminol chemiluminescence (ECL) gave the best resolution of the specific signal. The other systems were mainly hampered by a high diffusion of the reaction product over the tissue section. Unfortunately, in this case, the high molecular weight polymers tested were inefficient. However, the addition of polyvinylalcohol (PVA) or polyvinylpyrrolidone (PVP) significantly improved respectively the definition and intensity of ECL photon emission. We demonstrate that chemiluminescence gives a morphological resolution allowing histological examination. The extension of this new application, now depends on physicochemical adaptation of chemiluminescent reagents to the constraints of tissue detection.

Для цитирования: Lamarcq L, Lorimier P, Negoescu A, Labat-Moleur F, Durrant I, Brambilla E. Comparison of seven bio- and chemiluminescent reagents for in situ detection of antigens and nucleic acids.. Journal of bioluminescence and chemiluminescence. 1995. DOI: 10.1002/bio.1170100408.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.