Stapler size independently predicts postoperative complications following stapled ileocolic anastomosis: A retrospective cohort study.
Аннотация
AIM: Staplers used in ileocolic anastomosis construction differ in length and height. We assessed the impact of stapler type in creating ileocolic anastomoses on postoperative outcomes.
METHODS
This retrospective cohort study of an Institutional Review Board approved database included patients who underwent laparoscopic right colectomy for cancer between January 2011 and August 2021. All patients had construction of extracorporeal antiperistaltic stapled ileocolic anastomosis using a linear cutting stapler. Main outcome measures were short-term (<30 day) morbidity and mortality.
RESULTS
In all, 270 patients (136 men; median age 70.2 years) were included. A 75 mm stapler was used in 49 (18.1%) patients, 80 mm in 97 (35.9%) and 100 mm in 124 (45.9%). Blue cartridge (stapler height 3.5 mm) was used in 175 (64.5%) and green cartridge (4.8 mm) in 18 (7%) patients; this information was unavailable in 77 (28.5%) cases. Apical enterotomy closure was performed by linear stapler in 54% and linear cutting stapler in 46%. Apical staple line reinforcement or imbrication suturing was used in 26.3%. The overall postoperative complication rate was 28.9%. The anastomotic leak rate was 2.6%. Independent predictors of complications after laparoscopic right colectomy were older age (OR 1.03, 95%CI 1-1.06; P = 0.01), extended colectomy (OR 2.76, 95%CI 1.07-7.08; P = 0.035) and emergency surgery (OR 4.5, 95%CI 1.3-14.9; P = 0.014). A 100-mm linear cutting stapler was an independent protective factor against postoperative complications (OR 0.3, 95%CI 0.18-0.85; P = 0.019). Stapler height and closure technique of apical enterotomy did not affect postoperative complications.
CONCLUSION
Independent predictors of complications after laparoscopic right colectomy were older age, extended colectomy and emergency surgery. Using a 100 mm stapler was an independent protective factor against postoperative complications.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.