m+Medelevator.RU
← Поиск публикаций
Annals of surgical oncology · 2020

Four-Point Computed Tomography Scores for Evaluation of Occult Peritoneal Metastasis in Patients with Gastric Cancer: A Region-to-Region Comparison with Staging Laparoscopy.

Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Li Zi-Yu, Tang Lei, Li Zhe-Min, Li Yan-Ling, Fu Jia, Zhang Yan, Li Xiao-Ting, Ying Xiang-Ji, Ji Jia-Fu

Аннотация

BACKGROUND: Preoperative diagnosis of peritoneal metastasis with gastric cancer remains challenging. This study explored the abnormal computed tomography (CT) signs of occult peritoneal metastasis (OPM) and evaluated it by region-to-region comparison using staging laparoscopy, from which a 4-point CT score system was developed.

METHODS: Patients with advanced gastric cancer (stage cT ≥ 2M0) diagnosed by CT were enrolled in the study. Occult peritoneal metastasis detected during staging laparoscopy was compared with preoperative CT to investigate the presence of abnormal signs by a region-to-region comparison. A 4-point CT score system was developed to define the radiologic characteristics. Subsequently, the diagnostic efficacy of the CT score system was prospectively verified.

RESULTS: In this study, 57 OPM regions were detected by staging laparoscopy in 33 of the 385 enrolled patients. The greater omentum was the most frequent site of OPM (38.60%, 22/57), which usually exhibited a smudge-like ground-glass opacity (S-GGO) (90.91%, 20/22) with a mean CT score of 2.14. The parietal and perihepatic peritoneum was the second most common site (22.81%, 13/57). A 4-point CT score system was developed based on the results. A cutoff CT score of 2 or higher was associated with a false-negative rate of 2% (2/99). This CT score system had a sensitivity of 87.5% and a specificity of 76.4% for an OPM-positive diagnosis (area under the curve, 0.848). The agreement between two radiologists on the assigned final score was 76.2% (kappa, 0.5).

CONCLUSIONS: Patients with OPM mostly exhibited S-GGO on CT, which should be interpreted cautiously. The 4-point CT score system may improve the pretreatment evaluation of occult peritoneal metastasis, and staging laparoscopy might not be necessary for patients with a score lower than 2.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты