MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jconrel.2019.03.032

Медицинская библиотека · Journal of controlled release : official journal of the Controlled Release Society · 2019

Characterisation of nasal devices for delivery of insulin to the brain and evaluation in humans using functional magnetic resonance imaging.

Wingrove Jed, Swedrowska Magda, Scherließ Regina, Parry Mark, Ramjeeawon Mervin, Taylor David, Gauthier Gregoire, Brown Louise, Amiel Stephanie, Zelaya Fernando, Forbes Ben

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

This study aimed to characterise three nasal drug delivery devices to evaluate their propensity to deliver human insulin solutions to the nasal cavity for redistribution to the central nervous system. Brain delivery was evaluated using functional magnetic resonance imaging to measure regional cerebral blood flow. Intranasal insulin administration has been hypothesised to exploit nose-to-brain pathways and deliver drug directly to the brain tissue whilst limiting systemic exposure. Three nasal pump-actuator configurations were compared for delivery of 400 IU/mL insulin solution by measuring droplet size distribution, plume geometry, spray pattern and in vitro deposition in a nasal cast. The device with optimal spray properties for nose to brain delivery (spray angle between 30° and 45°; droplet size between 20 and 50 μm) also favoured high posterior-superior deposition in the nasal cast and was utilised in a pharmacological magnetic resonance imaging study. Functional magnetic resonance imaging in healthy male volunteers showed statistically significant decreases in regional cerebral blood flow within areas dense in insulin receptors (bilateral amygdala) in response to intranasally administered insulin (160 IU) compared to saline (control). These changes correspond to the expected effects of insulin in the brain and were achieved using a simple nasal spray device and solution formulation. We recommend that a thorough characterisation of nasal delivery devices and qualitative/quantitative assessment of the administered dose is reported in all studies of nose to brain delivery so that responses can be evaluated with respect to posology and comparison between studies is facilitated.

Для цитирования: Wingrove Jed, Swedrowska Magda, Scherließ Regina, Parry Mark, Ramjeeawon Mervin, Taylor David, Gauthier Gregoire, Brown Louise, Amiel Stephanie, Zelaya Fernando, Forbes Ben. Characterisation of nasal devices for delivery of insulin to the brain and evaluation in humans using functional magnetic resonance imaging.. Journal of controlled release : official journal of the Controlled Release Society. 2019. DOI: 10.1016/j.jconrel.2019.03.032.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.