MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12903-024-04476-3

Медицинская библиотека · BMC oral health · 2024

Evaluation of the resection plane three-dimensional positional accuracy using a resection guide directional guidance slot; a randomized clinical trial.

El-Mahallawy Yehia, Dessoky Noha Y, Abdelrahman Hams H, Al-Mahalawy Haytham

СтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

AIM: The study was performed to compare the mandibular resection guide with a directional guidance slot with the conventional guide regarding three-dimensional positional accuracy.

MATERIALS AND

METHODS

Twenty-six patients with lateral segmental mandibular defects were selected, and randomly allocated into two groups. All defects were managed with preoperative virtual surgical planning. Resection in the test group was conducted using a resection guide with a directional guidance slot, while a conventional resection guide design was utilized in the control group. The linear and angular deviation of the osteotomy planes was analyzed for both groups, along with the accuracy of the insertion of the reconstruction bone block in the resected defect. Data were documented, absolute deviation was calculated, statistical analysis was performed and significance was set at the 5% level.

RESULTS

The cases conducted with a directional guidance templet reported a statistically significant difference when compared to the conventional edge-cutting guide regarding the linear and angular spatial osteotomy plane position (P < 0.001). The defect span analysis reported excellent levels of agreement in both groups (ICC = 1.00, ICC = 0.995), however, the difference between the groups was statistically significant (P < 0.001).

CONCLUSION

The study demonstrated the enhanced positional accuracy of the resection plane and reconstruction block placement when a directional slot is incorporated in the computer-generated resection guide.

Для цитирования: El-Mahallawy Yehia, Dessoky Noha Y, Abdelrahman Hams H, Al-Mahalawy Haytham. Evaluation of the resection plane three-dimensional positional accuracy using a resection guide directional guidance slot; a randomized clinical trial.. BMC oral health. 2024. DOI: 10.1186/s12903-024-04476-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.