Optimization of cerebral oxygenation based on regional cerebral oxygen saturation monitoring during carotid endarterectomy: a Phase III multicenter, double-blind randomized controlled trial.

Le Teurnier Yann, Rozec Bertrand, Degryse Cecile, Levy François, Miliani Youcef, Godet Gilles, Daccache Georges, Truc Cyrille, Steinmetz Eric, Ouattara Alexandre, Cholley Bernard, Malinovsky Jean-Marc, Portier Denis, Dupont Gregory, Liutkus Darius, Viard Pierre, Pere Morgane, Daumas-Duport Benjamin, Magras Pierre-Aubin, Vourc'h Mickael, EMOCAR Study Group

СтатьяРандомизированное исследованиеМногоцентровое исследованиеКлиническое исследование III фазыПеревод пока не подготовлен

Аннотация

BACKGROUND

Whether the optimization of cerebral oxygenation based on regional cerebral oxygen saturation (rSO2) monitoring reduces the occurrence of cerebral ischemic lesions is unknown.

METHODS

This multicenter, randomized, controlled trial recruited adults admitted for scheduled carotid endarterectomy. Patients were randomized between the standard of care or optimization of cerebral oxygenation based on rSO2 monitoring using near-infrared spectroscopy. In the intervention group, in case of a decrease in rSO2 in the intervention, the following treatments were sequentially recommended: (1) increasing oxygenotherapy, (2) reducing the tidal volume, (3) legs up-raising, (4) performing a fluid challenge and (5) initiating vasopressor support. The primary endpoint was the number of new cerebral ischemic lesions detected using magnetic resonance imaging pre- and postoperatively. Secondary endpoints included new neurological deficits and mortality on day 120 after surgery.

RESULTS

Among the 879 patients who were randomized, 665 (75.7%) were men. There was no statistically significant difference between groups for the mean number of new cerebral ischemic lesions per patient up to 3 days after surgery: 0.35 (±1.05) in the standard group vs. 0.58 (±2.83), in the NIRS group; mean difference, 0.23 [95% CI, -0.06 to 0.52]; estimate, 0.22 [95% CI, -0.06 to 0.50]. New neurological deficits up to day 120 after hospital discharge were not different between the groups: 15 (3,39%) in the standard group vs. 42 (5,49%) in the NIRS group; absolute difference, 2,10 [95% CI, -0,62 to 4,82]. There was no significant difference between groups for the median [IQR] hospital length of stay: 4.0 [4.0-6.0] in the standard group vs. 5.0 [4.0-6.0] in the NIRS group; mean difference, -0.11 [95% CI, -0.65 to 0.44]. The mortality rate on day 120 was not different between the standard group (0.68%) vs. the NIRS group (0.92%); absolute difference = 0.24% [95% CI, -0.94 to 1.41].

CONCLUSIONS

Among patients undergoing carotid endarterectomy, optimization of cerebral oxygenation based on rSO2 did not reduce the occurrence of cerebral ischemic lesions postoperatively compared with controlled hypertensive therapy.

TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT01415648.

Для цитирования: Le Teurnier Yann, Rozec Bertrand, Degryse Cecile, Levy François, Miliani Youcef, Godet Gilles, Daccache Georges, Truc Cyrille, Steinmetz Eric, Ouattara Alexandre, Cholley Bernard, Malinovsky Jean-Marc, Portier Denis, Dupont Gregory, Liutkus Darius, Viard Pierre, Pere Morgane, Daumas-Duport Benjamin, Magras Pierre-Aubin, Vourc'h Mickael, EMOCAR Study Group. Optimization of cerebral oxygenation based on regional cerebral oxygen saturation monitoring during carotid endarterectomy: a Phase III multicenter, double-blind randomized controlled trial.. Anaesthesia, critical care & pain medicine. 2024. DOI: 10.1016/j.accpm.2024.101388.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.