MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/rli.0000000000001083

Медицинская библиотека · Investigative radiology · 2024

Evaluation of the Contrast Enhancement Performance of Gadopiclenol for Magnetic Resonance Angiography in Healthy Rabbits and Pigs.

Hugon Gaëlle, Adriaensen Hans, Wintrebert Mélody, Arnould Laurent, Serfaty Jean-Michel, Robert Philippe

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

Unexpected accumulations of gadolinium in various organs were reported after the administration of gadolinium-based contrast agents, making desirable to reduce the dose while maintaining equivalent diagnostic performance. The aim of this study was to evaluate the contrast enhancement performance of high relaxivity gadopiclenol compared with gadoterate meglumine in abdominal contrast-enhanced magnetic resonance angiography (CE-MRA).

MATERIALS AND

METHODS

In a first study in healthy rabbits, axial 3D gradient echo sequences were applied at 4.7 T to study arterial enhancement as a function of gadopiclenol dose (0.025, 0.05, 0.075, and 0.1 mmol Gd/kg) or gadoterate meglumine at 0.1 mmol Gd/kg (n = 5-6/group). The increase in signal-to-noise ratio (ΔSNR) in the aorta at the first pass was measured and compared. In a second, crossover study in 6 healthy pigs, abdominal CE-MRA sequences were acquired at 3 T with gadopiclenol at 0.05 mmol Gd/kg or gadoterate meglumine at 0.1 mmol Gd/kg at a 1-week interval. Quantitatively on the maximum intensity projection (MIP) images, the mean MIP SNR within the aorta of both groups was compared. Qualitatively, a blinded comparison of the angiograms was performed by an experienced radiologist to determine the preferred contrast agent.

RESULTS

In the rabbit, ∆SNR is linearly correlated with the gadopiclenol dose ( P = 0.0010). Compared with gadoterate meglumine 0.1 mmol Gd/kg, an increase in the ∆SNR is observed after 0.05, 0.075, and 0.1 mmol Gd/kg of gadopiclenol (+63% P = 0.0731, +78% P = 0.0081, and +72% P = 0.0773, respectively), whereas at 0.025 mmol Gd/kg, ∆SNR is in the same range as with gadoterate meglumine 0.1 mmol Gd/kg (+15% P > 0.9999). In pigs, contrast enhancement after gadopiclenol at 0.05 mmol/kg is +22% superior to MIP SNR after gadoterate meglumine at 0.1 mmol Gd/kg ( P = 0.3095). Qualitatively, a preference was shown for gadopiclenol images (3/6) over the gadoterate meglumine examinations (1/6), with no preference being shown for the remainder (2/6).

CONCLUSIONS

First-pass CE-MRA is feasible with gadopiclenol at 0.05 mmol Gd/kg with at least the same arterial signal enhancement and image quality as gadoterate meglumine at 0.1 mmol Gd/kg.

Для цитирования: Hugon Gaëlle, Adriaensen Hans, Wintrebert Mélody, Arnould Laurent, Serfaty Jean-Michel, Robert Philippe. Evaluation of the Contrast Enhancement Performance of Gadopiclenol for Magnetic Resonance Angiography in Healthy Rabbits and Pigs.. Investigative radiology. 2024. DOI: 10.1097/rli.0000000000001083.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.