MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3233/xst-210867

Медицинская библиотека · Journal of X-ray science and technology · 2021

Stereotactic body radiation therapy for non-small cell lung cancer using the non-coplanar radiation of Cyberknife and Varian linac.

Shao Wencheng, Chen Ziyin, Bai Yanchun, Xu Bingchen, Xu Lili, Zhao Qiushuang, Wang Yang, Tang Xiaobin

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: This study aims to evaluate the planned dose of stereotactic body radiation therapy (SBRT) for treating early peripheral non-small cell lung cancer (NSCLC) using the non-coplanar radiation from Cyberknife and Varian linac. Moreover, this study investigates whether Cyberknife and Varian linac are qualified for non-coplanar radiation SBRT for treating early peripheral NSCLC, and which one is better for protecting organs at risk (OARs).

METHODS

Retrospective analysis was performed based on the Cyberknife radiation treatment plans (RTPs) and Varian Eclipse RTPs of 10 patients diagnosed with early peripheral NSCLC. The dose distributions in the target and OARs were compared between the RTPs of Cyberknife and Varian Eclipse using Mim medical imaging software.

RESULTS

For PTV, no significant difference in D98 and D95 between the Cyberknife and Eclipse was observed (t = -0.35, -1.67, P > 0.05). The homogeneity indexes (HIs) of Cyberknife plans are higher (t = 71.86, P < 0.05) than those of Eclipse plans. The V10, V15, V20, V25, V30 and Dmean of the lung with NSCLC and the V20 of the whole lung for Cyberknife were less than those for Eclipse (t = -4.73, -5.62, -7.75, -6.38, -6.89, -3.14, -7.09, respectively, P < 0.05). Cyberknife plans have smaller spinal cord Dmax, trachea Dmax, heart Dmax, chest wall Dmax (t = -2.49, -2.57, -3.71, -3.56, respectively, P < 0.05) and esophagus Dmax (t = -1.95, P > 0.05) than Varian Eclipse plans.

CONCLUSION

To fulfill SBRT by non-coplanar radiation, Cyberknife is recommended for the institutions equipped with Cyberknife, while Varian linac can be applied for the institutions that have not adopted Cyberknife in clinical radiotherapy yet.

Для цитирования: Shao Wencheng, Chen Ziyin, Bai Yanchun, Xu Bingchen, Xu Lili, Zhao Qiushuang, Wang Yang, Tang Xiaobin. Stereotactic body radiation therapy for non-small cell lung cancer using the non-coplanar radiation of Cyberknife and Varian linac.. Journal of X-ray science and technology. 2021. DOI: 10.3233/xst-210867.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.