Tracheal pressure generated by high-flow nasal cannula in 3D-Printed pediatric airway models.

Gray Alan J, Nielsen Katie R, Ellington Laura E, Earley Marisa, Johnson Kaalan, Smith Lincoln S, DiBlasi Rob M

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

Heated and humidified high flow nasal cannula (HFNC) is an increasingly used form of noninvasive respiratory support with the potential to generate significant tracheal pressure. The aim of this study was to quantify the pressure generated by HFNC within the trachea in anatomically correct, pediatric airway models.

METHODS

3D-printed upper airway models of a preterm neonate, term neonate, toddler, and small child were connected to a spontaneous breathing computerized lung model at age-appropriate ventilation settings. Two commercially available HFNC systems were applied to each airway model at increasing flows and the positive end-expiratory pressure (PEEP) was recorded at the level of the trachea.

RESULTS

Increasing HFNC flow produced a quadratically curved increase in tracheal pressure in closed-mouth models. The maximum flow tested in each model generated a tracheal pressure of 7 cm H2O in the preterm neonate, 10 cm H2O in the term neonate, 9 cm H2O in the toddler, and 24 cm H2O in the small child. Tracheal pressure decreased by at least 50% in open-mouth models.

CONCLUSIONS

HFNC was found to demonstrate a predictable flow-pressure relationship that achieved sufficient distending pressure to consider treatment of pediatric obstructive sleep apnea and tracheomalacia in the closed-mouth models tested.

Для цитирования: Gray Alan J, Nielsen Katie R, Ellington Laura E, Earley Marisa, Johnson Kaalan, Smith Lincoln S, DiBlasi Rob M. Tracheal pressure generated by high-flow nasal cannula in 3D-Printed pediatric airway models.. International journal of pediatric otorhinolaryngology. 2021. DOI: 10.1016/j.ijporl.2021.110719.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.