MedElevator Войти в исследования
← Поиск публикаций

DOI 10.7754/clin.lab.2015.150808

Медицинская библиотека · Clinical laboratory · 2016

Comparison of In-House Multiplex Real Time PCR, Diagcor GenoFlow HPV Array Test and INNO-LiPA HPV Genotyping Extra Assays with LCD- Array Kit for Human Papillomavirus Genotyping in Cervical Liquid Based Cytology Specimens and Genital Lesions in Tehran, Iran.

Sohrabi Amir, Rahnamaye-Farzami Marjan, Mirab-Samiee Siamak, Mahdavi Saeed, Babaei Monireh

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Human papillomavirus is a major etiologic agent for some human common cancers. Cervical precancer and cancer is the most prevalent dysplasia by HPV genotypes. Various rapid and sensitive methods have been developed into readily HPV genotyping.

METHODS

In the present study, we compared the performance of Real Time PCR, GenoFlow HPV Array, and INNO-LiPA HPV Genotyping Extra Assays with LCD- Array.

RESULTS

From 108 cervical samples, HPV was detected in 33 women (30.55%). Among detected HPV genotypes, HPV 6 and 11 were dominant genotypes. Comparing these methods revealed that for Real Time PCR, Genoflow, and INNO-LiPA in comparison with LCD Array, sensitivity and specificity were 94.2%, 93%; 76.7%, 93%; 64%, 96.5%, respectively. Overall, accuracy and precision of these methods were more than 80% and 90%, respectively.

CONCLUSIONS

It seems that these methods are reliable and suitable for detection and genotyping of HPVs in cervical disorders and other dysplasia associated with human papillomaviruses.

Для цитирования: Sohrabi Amir, Rahnamaye-Farzami Marjan, Mirab-Samiee Siamak, Mahdavi Saeed, Babaei Monireh. Comparison of In-House Multiplex Real Time PCR, Diagcor GenoFlow HPV Array Test and INNO-LiPA HPV Genotyping Extra Assays with LCD- Array Kit for Human Papillomavirus Genotyping in Cervical Liquid Based Cytology Specimens and Genital Lesions in Tehran, Iran.. Clinical laboratory. 2016. DOI: 10.7754/clin.lab.2015.150808.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.