MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.mvr.2018.01.007

Медицинская библиотека · Microvascular research · 2018

Inter-visit variability of conjunctival microvascular hemodynamic measurements in healthy and diabetic retinopathy subjects.

Khansari Maziyar M, Tan Michael, Karamian Preny, Shahidi Mahnaz

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Conjunctival microcirculation imaging provides a non-invasive means for detecting hemodynamic alterations due to systemic and ocular diseases. However, reliable longitudinal monitoring of hemodynamic changes due to disease progression requires establishment of measurement variability over time. The purpose of the current study was to determine inter-visit variability of conjunctival microvascular hemodynamic measurements in non-diabetic control (NC, N = 7) and diabetic retinopathy (DR, N = 10) subjects. Conjunctival microvascular imaging was performed during 2 visits, which were 17 ± 12 weeks apart. Images were analyzed to determine vessel diameter (D), axial blood velocity (V), blood flow (Q), wall shear rate (WSR) and wall shear stress (WSS). The inter-visit variability was determined based on mean inter-visit differences. In NC, inter-visit variability of D, V, Q, WSR and WSS were 0.2 ± 0.5 μm, -0.01 ± 0.16 mm/s, -8 ± 46 pl/s, -3 ± 46 s-1 and -0.01 ± 0.10 dyne/cm2, respectively. Inter-visit variability of D, V, Q, WSR and WSS were beyond the normal 95% confidence limits in 60%, 20%, 40%, 20% and 20% of DR subjects, respectively. The variability of hemodynamic measurements over time was established in non-diabetic subjects, suggestive of the potential of the method for detecting longitudinal changes due to progression of DR.

Для цитирования: Khansari Maziyar M, Tan Michael, Karamian Preny, Shahidi Mahnaz. Inter-visit variability of conjunctival microvascular hemodynamic measurements in healthy and diabetic retinopathy subjects.. Microvascular research. 2018. DOI: 10.1016/j.mvr.2018.01.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.