MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/0003489420938820

Медицинская библиотека · The Annals of otology, rhinology, and laryngology · 2020

Prospective Evaluation of a Smartphone Otoscope for Home Tympanostomy Tube Surveillance: A Pilot Study.

Don Debra M, Koempel Jeffrey A, Fisher Laurel M, Wee Choo Phei, Osterbauer Beth

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

Recent technological advances have led to the capability of performing high resolution imaging of the tympanic membrane. Smartphone technologies and applications have provided the opportunity to capture digital images and easily share them. The smartphone otoscope device was developed as a simple system that can convert a smartphone into a digital otoscope. This device has the prospective ability to improve physician-patient communication and assist with the diagnosis and management of ear disease. Our objective was to evaluate the feasibility and physician/parental satisfaction using the Cellscope® smartphone attachment for at home tympanostomy tube monitoring.

METHODS

Children between 6 months and 15 years of age at an urban tertiary children's hospital that were scheduled for bilateral tympanostomy tube insertion or underwent bilateral tympanostomy tube surgery were prospectively enrolled in the study. Comparisons were made between parental home-recorded videos and findings during in-office otoscopy. Two independent otolaryngologists reviewed the videos and concordance between inter-rater agreements was calculated. Acceptability and use questionnaires were administered to physicians and parents.

RESULTS

There was good intra-rater agreement between traditional otoscopy and video-otoscopy for tube extruding, tube blocked and tube extruded with at least 80% agreement (P < .05) and excellent inter-rater agreement between physicians for nearly all tube variables (P < .0001) There was a high degree of satisfaction with this mode of surveillance. Parents and physicians agreed that the CellScope® smartphone was easy to use, helpful with the occurrence of acute events, and appeared to improve quality of care.

CONCLUSIONS

The CellScope® smartphone is feasible for use in tympanostomy tube surveillance. Use of the device may allow otolaryngologists to easily follow a child's tympanostomy tube remotely over time and offer greater parental satisfaction.

Для цитирования: Don Debra M, Koempel Jeffrey A, Fisher Laurel M, Wee Choo Phei, Osterbauer Beth. Prospective Evaluation of a Smartphone Otoscope for Home Tympanostomy Tube Surveillance: A Pilot Study.. The Annals of otology, rhinology, and laryngology. 2020. DOI: 10.1177/0003489420938820.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.