MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1152/jappl.1981.50.3.580

Медицинская библиотека · Journal of applied physiology: respiratory, environmental and exercise physiology · 1981

Relative responses of aortic body and carotid body chemoreceptors to carboxyhemoglobinemia.

Lahiri S, Mulligan E, Nishino T, Mokashi A, Davies R O

СтатьяПоддержка службы здравоохранения СШАПеревод пока не подготовлен

Аннотация

The effects of carbon monoxide inhalation and of consequent carboxyhemoglobinemia (HbCO) on the discharge rates of aortic body and carotid body chemoreceptor afferents were investigated in 18 anesthetized cats. In 10 experiments both aortic and carotid chemoreceptor activities were monitored simultaneously. Carbon monoxide inhalation during normoxia always stimulated aortic chemoreceptors before carotid chemoreceptors, and the steady-state response of aortic chemoreceptors to HbCO was greater than that of most carotid chemoreceptors. Only 2 of the 18 carotid chemoreceptor fibers tested showed a distinct increase in activity in response to moderate increases in HbCO%. Thus, oxyhemoglobin contributed substantially to maintain tissue PO2 of all aortic chemoreceptors and of a few carotid chemoreceptors. Hyperoxia diminished the response of both aortic and carotid chemoreceptors to HbCO, indicating a lowered tissue PO2 as the stimulus source. We hypothesize that the aortic bodies have a much lower perfusion relative to their O2 utilization compared to the carotid bodies. As a consequence, the aortic chemoreceptors are able to act as a sensitive monitor of O2 delivery and to generate a circulatory chemoreflex for O2 homeostasis. carotid chemoreceptors monitor O2 tension and initiate strong reflex effects on the level of ventilation.

Для цитирования: Lahiri S, Mulligan E, Nishino T, Mokashi A, Davies R O. Relative responses of aortic body and carotid body chemoreceptors to carboxyhemoglobinemia.. Journal of applied physiology: respiratory, environmental and exercise physiology. 1981. DOI: 10.1152/jappl.1981.50.3.580.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.