DOI 10.1016/s0212-6982(04)72312-5
[Value of thallium 201-SPECT in typing brain space-occupying lesions].
Аннотация
OBJECTIVE
This study was designed to assess the diagnostic accuracy of single photon emission computed tomography with Tl-201 (SPECT Tl-201) to establish the tumoral or non-tumoral nature of brain space occupying lesions in comparison with usual diagnostic techniques.
MATERIAL AND
METHODS
The study population consisted of 37 patients, 24 men (64.9 %) and 13 women (35.1 %), mean age 48 +/- 16 years. After establishing the clinical and radiological diagnosis of brain lesion, all patients underwent SPECT Tl-201, evaluating it only by subjective analysis and blinded to neuroestructural techniques. After surgical resection all patients were evaluated anatomopathologically to establish the histologic nature.
RESULTS
The sensitivity of SPECT Tl-201 (0.87) was higher than standard neuroimaging techniques (0.78). Specificity (0.43), positive (0.87) and negative (0.43) predictive values of SPECT were similar to neuroestructural procedures (MRI and CT scan) with 0.43, 0.82 and 0.38 values. Tumoral disease prevalence was 0.81. Neuroestructural procedures were non-conclusive in 18.9 % of the studies. No non-conclusive results were obtained with SPECT Tl-201.
CONCLUSIONS
SPECT Tl-201 is a diagnostic procedure of high sensitivity to establish the tumoral nature of brain lesions, with poor specificity, similar to structural X-ray techniques.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.