MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.radonc.2021.03.001

Медицинская библиотека · Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology · 2021

Ablative radiotherapy for ultracentral lung cancers: Dosimetric, geometric, and volumetric predictors of outcomes and toxicity.

Breen William G, Jeans Elizabeth B, Gergelis Kimberly R, Garces Yolanda I, Park Sean S, Merrell Kenneth W, Peikert Tobias D, Mansfield Aaron S, Wigle Dennis A, Harmsen William S, Ellerbusch David C, Olivier Kenneth R, John Lucido J, Owen Dawn

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Ultracentral lung cancers arise near the proximal bronchial tree (PBT), trachea, or esophagus, and have been associated with worse outcomes and increased toxicity after radiotherapy. We sought to associate dosimetric and anatomic factors with oncologic outcomes and toxicities.

METHODS

One-hundred ten patients treated with ablative, curative-intent radiotherapy for ultracentral, node-negative, non-small cell lung cancer were included. Dosimetric and geometric data obtained using custom software that calculated volumes of target structures and organs-at-risk and measured the shortest vector length between these volumes were associated with outcomes and toxicity.

RESULTS

Common dose/fractionation schemes included 50 Gy in 5 fractions (57%), 60 Gy in 8 fractions (15%), and 48 Gy in 4 fractions (13%). Overall survival at 1, 2, and 5 years was 78%, 57%, and 32%, respectively. Factors significantly associated with death included endobronchial tumor, gross tumor volume (GTV) or planning target volume (PTV) contacting PBT, shorter distance from GTV to PBT or esophagus, volume of PBT receiving prescription dose, higher pericardium max dose, lung V20Gy, and mean lung dose. Local progression at 1, 2, and 5 years was 4%, 16%, and 21%. Factors associated with local progression were lower GTV minimum dose and higher GTV/PTV volume ratio. Acute and late grade 2 + toxicity was seen in 18% and 27%, respectively. Four patients (4%) had fatal toxicity.

CONCLUSIONS

Lower GTV minimum dose and smaller volumetric PTV expansions may increase risk of local progression, and should be balanced against normal tissue doses including pericardium maximum dose, lung V20Gy, and mean lung dose.

Для цитирования: Breen William G, Jeans Elizabeth B, Gergelis Kimberly R, Garces Yolanda I, Park Sean S, Merrell Kenneth W, Peikert Tobias D, Mansfield Aaron S, Wigle Dennis A, Harmsen William S, Ellerbusch David C, Olivier Kenneth R, John Lucido J, Owen Dawn. Ablative radiotherapy for ultracentral lung cancers: Dosimetric, geometric, and volumetric predictors of outcomes and toxicity.. Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. 2021. DOI: 10.1016/j.radonc.2021.03.001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.