MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.brachy.2019.05.009

Медицинская библиотека · Brachytherapy · 2019

A surrogate urethra for real-time planning of high-dose-rate prostate brachytherapy.

Halperin Heather, Hilts Michelle, Crook Juanita, Batchelar Deidre, Tisseverasinghe Steven, Tetreault-LaFlamme Audrey, Bachand Francois

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: This study characterizes prostatic urethra cross-section to develop a surrogate urethra for accurate prediction of urethral dose during real-time high-dose-rate prostate brachytherapy.

MATERIALS AND

METHODS

Archived preoperative transrectal ultrasound images from 100 patients receiving low-dose-rate prostate brachytherapy were used to characterize the prostatic urethra, contoured on ultrasound using aerated gel. Consensus contours, defined using majority vote, described commonalities in cross-sectional shape across patients. Potential simplified surrogates were defined and evaluated against the true urethra. The best performing surrogate, a circle of varying size (CS) was retrospectively contoured on 85 high-dose-rate prostate brachytherapy treatment plans. Dose to this recommended surrogate was compared with urethral doses estimated by the standard 6 mm circle surrogate.

RESULTS

Clear variation in urethral cross-sectional shape was observed along its length and between patients. The standard circle surrogate had low predictive sensitivity (61.1%) compared with true urethra because of underrepresentation of the verumontanum midgland. The CS best represented the true urethra across all validation metrics (dice: 0.73, precision: 67.0%, sensitivity: 83.2%, conformity: 0.78). Retrospective evaluation of planned doses using the CS surrogate resulted in significant differences in all reported urethral dose parameters compared with the standard circle, with the exception of D100%. The urethral dose limit (115%) was exceeded in 40% of patients for the CS surrogate.

CONCLUSIONS

The proposed CS surrogate, consisting of circles of varying diameter, is simple yet better represents the true urethra compared with the standard 6 mm circle. Higher urethral doses were predicted using CS, and the improved accuracy of CS may offer increased predictive power for urethral toxicity, a subject of future work.

Для цитирования: Halperin Heather, Hilts Michelle, Crook Juanita, Batchelar Deidre, Tisseverasinghe Steven, Tetreault-LaFlamme Audrey, Bachand Francois. A surrogate urethra for real-time planning of high-dose-rate prostate brachytherapy.. Brachytherapy. 2019. DOI: 10.1016/j.brachy.2019.05.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.