MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3348/kjr.2008.9.3.212

Медицинская библиотека · Korean journal of radiology · 2008

MR imaging of the internal auditory canal and inner ear at 3T: comparison between 3D driven equilibrium and 3D balanced fast field echo sequences.

Byun Jun Soo, Kim Hyung Jin, Yim Yoo Jeong, Kim Sung Tae, Jeon Pyoung, Kim Keon Ha, Kim Sam Soo, Jeon Yong Hwan, Lee Jiwon

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To compare the use of 3D driven equilibrium (DRIVE) imaging with 3D balanced fast field echo (bFFE) imaging in the assessment of the anatomic structures of the internal auditory canal (IAC) and inner ear at 3 Tesla (T).

MATERIALS AND

METHODS

Thirty ears of 15 subjects (7 men and 8 women; age range, 22-71 years; average age, 50 years) without evidence of ear problems were examined on a whole-body 3T MR scanner with both 3D DRIVE and 3D bFFE sequences by using an 8-channel sensitivity encoding (SENSE) head coil. Two neuroradiologists reviewed both MR images with particular attention to the visibility of the anatomic structures, including four branches of the cranial nerves within the IAC, anatomic structures of the cochlea, vestibule, and three semicircular canals.

RESULTS

Although both techniques provided images of relatively good quality, the 3D DRIVE sequence was somewhat superior to the 3D bFFE sequence. The discrepancies were more prominent for the basal turn of the cochlea, vestibule, and all semicircular canals, and were thought to be attributed to the presence of greater magnetic susceptibility artifacts inherent to gradient-echo techniques such as bFFE.

CONCLUSION

Because of higher image quality and less susceptibility artifacts, we highly recommend the employment of 3D DRIVE imaging as the MR imaging choice for the IAC and inner ear.

Для цитирования: Byun Jun Soo, Kim Hyung Jin, Yim Yoo Jeong, Kim Sung Tae, Jeon Pyoung, Kim Keon Ha, Kim Sam Soo, Jeon Yong Hwan, Lee Jiwon. MR imaging of the internal auditory canal and inner ear at 3T: comparison between 3D driven equilibrium and 3D balanced fast field echo sequences.. Korean journal of radiology. 2008. DOI: 10.3348/kjr.2008.9.3.212.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.