DOI 10.1007/s00247-021-05032-9
Immediate chest radiograph interpretation by radiographers improves patient safety related to nasogastric feeding tube placement in children.
Аннотация
BACKGROUND
Despite the publication of a national patient safety alert in 2016, inadvertent feeding through misplaced nasogastric tubes continues to occur, either through failure to review the radiograph, misinterpretation of it, or failure to communicate the results.
OBJECTIVE
The objectives were to determine whether training in a new pathway introduced to avoid these "never events" was followed and whether radiographer comments and prompt communication of results could reduce risk and improve patient safety in relation to nasogastric tube placement in children.
MATERIALS AND
METHODS
Following radiographer training in interpretation of nasogastric tube position and use of a commenting proforma and communication pathway, we reviewed all radiographs obtained to check nasogastric tubes performed over a 13-month period in children 0-16 years of age. Then we assessed accuracy of the radiographer comments, adherence to the pathway, and any practice change in children with misplaced nasogastric tubes.
RESULTS
We reviewed 282 nasogastric tube check radiographs. For 262 radiographs (92.9%) the pathway was followed correctly. Of the total 282 radiographs, 240 (85%) were immediately reported using the standardised commenting proforma, and 235 radiographer comments were affirmed by the radiologist (97% accuracy, confidence interval 0.95-0.99). Of the immediately reported radiographs, 213 (88.8%) nasogastric tubes were considered to be safe for use. Four (1.7%) of the immediately reported nasogastric tubes were misplaced in a bronchus, and the report communicated to the clinical team resulted in removal or re-siting of the tubes.
CONCLUSION
Nasogastric tube check radiographs in children can be reported accurately by radiographers trained in their interpretation and the results promptly communicated to clinical staff, improving safety in relation to nasogastric tube placement in children.