MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3171/jns.2003.99.2.0297

Медицинская библиотека · Journal of neurosurgery · 2003

An inflatable balloon catheter and liquid 125I radiation source (GliaSite Radiation Therapy System) for treatment of recurrent malignant glioma: multicenter safety and feasibility trial.

Tatter Stephen B, Shaw Edward G, Rosenblum Mark L, Karvelis Kastytis C, Kleinberg Lawrence, Weingart Jon, Olson Jeffrey J, Crocker Ian R, Brem Steven, Pearlman James L, Fisher Joy D, Carson Kathryn, Grossman Stuart A, New Approaches to Brain Tumor Therapy Central Nervous System Consortium

СтатьяПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАПеревод пока не подготовлен

Аннотация

OBJECT: In this study the authors evaluated the safety and performance of the GliaSite Radiation Therapy System (RTS) in patients with recurrent malignant brain tumors who were undergoing tumor resection.

METHODS

The GliaSite is an inflatable balloon catheter that is placed in the resection cavity at the time of tumor debulking. Low-dose-rate radiation is delivered with an aqueous solution of organically bound iodine-125 (lotrex [sodium 3-(125I)-iodo-4-hydroxybenzenesulfonate]), which are temporarily introduced into the balloon portion of the device via a subcutaneous port. Adults with recurrent malignant glioma underwent resection and GliaSite implantation. One to 2 weeks later, the device was filled with Iotrex for 3 to 6 days, following which the device was explanted. Twenty-one patients with recurrent high-grade astrocytomas were enrolled in the study and received radiation therapy. There were two end points: 1) successful implantation and delivery of brachytherapy; and 2) safety of the device. Implantation of the device, delivery of radiation, and the explantation procedure were well tolerated. At least 40 to 60 Gy was delivered to all tissues within the target volume. There were no serious adverse device-related events during brachytherapy. One patient had a pseudomeningocele, one patient had a wound infection, and three patients had meningitis (one bacterial, one chemical, and one aseptic). No symptomatic radiation necrosis was identified during 21.8 patient-years of follow up. The median survival of previously treated patients was 12.7 months (95% confidence interval 6.9-15.3 months).

CONCLUSIONS

The GliaSite RTS performs safely and efficiently. It delivers a readily quantifiable dose of radiation to tissue at the highest risk for tumor recurrence.

Для цитирования: Tatter Stephen B, Shaw Edward G, Rosenblum Mark L, Karvelis Kastytis C, Kleinberg Lawrence, Weingart Jon, Olson Jeffrey J, Crocker Ian R, Brem Steven, Pearlman James L, Fisher Joy D, Carson Kathryn, Grossman Stuart A, New Approaches to Brain Tumor Therapy Central Nervous System Consortium. An inflatable balloon catheter and liquid 125I radiation source (GliaSite Radiation Therapy System) for treatment of recurrent malignant glioma: multicenter safety and feasibility trial.. Journal of neurosurgery. 2003. DOI: 10.3171/jns.2003.99.2.0297.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.