DOI 10.1148/radiology.189.1.8372222
Imaging of the skin with 20-MHz US.
Аннотация
PURPOSE: The authors clinically evaluated a new high-frequency ultrasound (US) scanner to determine the value of US for dermatologic applications.
MATERIALS AND
METHODS
A 20-MHz US scanner was used to visualize normal skin at eight sites in 10 healthy volunteers and to evaluate 200 skin lesions (45 malignant, 155 benign).
RESULTS
In normal skin, the dermis was markedly echogenic and sharply demarcated from hypoechoic subcutaneous fat. The epidermis was not resolved except on the palm and sole. Only three superficial lesions were not identified with US; evaluation of another three was limited by shadowing. Thickness of the lesions visualized was 0.2-26.0 mm (mean, 1.9 mm +/- 2.6). Most lesions (77%) were hypoechoic, 9% were anechoic, 12% had mixed echogenicity, and 2% were isoechoic or hyperechoic.
CONCLUSION
The diagnostic role of high-frequency US appears limited. It did not help differentiate benign from malignant lesions, but it did enable accurate delineation of deep margins of lesions and allowed noninvasive measurement of thickness. These features may help in the preoperative evaluation of skin tumors and in monitoring the response to therapy for certain inflammatory conditions.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.