Diabetic medicine : a journal of the British Diabetic Association · 2025

Impact of Simplera Sync™ sensors and Extended™ Wear Infusion Sets on glycaemia and system performance of the MiniMed™ 780G system in children and young adults with previously high HbA1c.

СтатьяРандомизированное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Michaels Venus R, Boucsein Alisa, Zhou Yongwen, Jones Shirley D, Paul Ryan G, Wiltshire Esko, Jefferies Craig, de Bock Martin I, Wheeler Benjamin J

Аннотация

AIMS: The MiniMed™ 780G improves glycaemia and reduces burden in type 1 diabetes. We investigated how new all-in-one "Simplera Sync™" sensors and 7-day Extended™ Wear Infusion Sets (EIS) affect glycaemia and system performance in young people with previously elevated HbA1c levels (≥69 mmol/mol [≥8%]) after transitioning from 780G with Guardian 4™ sensors and 3-day infusion sets.

METHODS: We conducted an extension phase analysis in 75 participants (aged 7-25 years) initially enrolled in the CO-PILOT randomised controlled trial. For this analysis, baseline was defined as the period following the use of 780G with Guardian 4™ sensors and 3-day infusion sets. Participants then transitioned to 780G with Simplera Sync™ and EIS. We compared glycaemic and system performance outcomes from baseline to those after the transition to 780G with Simplera Sync™ and EIS.

RESULTS: Baseline HbA1c was 66.1 mmol/mol ± 14.2 mmol/mol and remained stable at 66.7 mmol/mol ± 11.2 mmol/mol after the transition (p = 0.38). Time in range (3.9-10.0 mmol/L [70-180 mg/dL]) at baseline was 58.5% ± 14.9% and 60.4% ± 15.7% after transition (p = 0.09). Time in tight range (3.9-7.8 mmol/L [70-140 mg/dL]) increased from 38.1% ± 13.1% at baseline to 40.5% ± 13.6% after the transition (p = 0.04). While using 780G with Simplera Sync™ and EIS, automation time increased from baseline 79.2% ± 25.9% to 85.8% ± 21.8% (p = 0.007), and sensor wear time from 80.7% ± 22.4% at baseline to 88.4% ± 17.2% (p < 0001).

CONCLUSIONS: Simplera Sync™ and EIS improved time in automation and sensor wear time when using 780G AHCL in this high-risk young population. This was associated with incremental improvement in time in tight range despite the challenges of this population.