Low-intensity, long-wavelength red light slows the progression of myopia in children: an Eastern China-based cohort.
Аннотация
PURPOSE: To determine the effect of low-intensity, long-wavelength red light therapy (LLRT) on the inhibition of myopia progression in children.
METHODS
A retrospective study was conducted. One hundred and five myopic children (spherical equivalent refractive error [SER] -3.09 ± 1.74 dioptres [D]; mean age, 9.19 ± 2.40 years) who underwent LLRT treatment (power 0.4 mW, wavelength 635 nm) twice per day for 3 min each session, with at least a 4-h interval between sessions, and a control group of 56 myopic children (SER -3.04 ± 1.66 D; mean age, 8.62 ± 2.45 years) were evaluated. Both groups wore single-vision distance spectacles. Each child returned for a follow-up examination every 3 months after the initial measurements for a total of 9 months.
RESULTS
At 9 months, the mean SER in the LLRT group was -2.87 ± 1.89 D, significantly greater than that of the control group (-3.57 ± 1.49 D, p < 0.001). Axial length (AL) changes were -0.06 ± 0.19 mm and 0.26 ± 0.15 mm in the LLRT group and control group (p < 0.001), respectively. The subfoveal choroidal thickness changed by 45.32 ± 30.88 μm for children treated with LLRT at the 9-month examination (p < 0.001). Specifically, a substantial hyperopic shift (0.31 ± 0.24 D and 0.20 ± 0.14 D, respectively, p = 0.02) was found in the 8-14 year olds compared with 4-7 year old children. The decrease in AL in subjects with baseline AL >24 mm was -0.08 ± 0.19 mm, significantly greater than those with a baseline AL ≤24 mm (-0.04 ± 0.18 mm, p = 0.03).
CONCLUSIONS
Repetitive exposure to LLRT therapy was associated with slower myopia progression and reduced axial growth after short durations of treatment. These results require further validation in randomised controlled trials.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.