The Validity and Reliability of a Real-Time Biofeedback System for Lumbopelvic Control Training in Baseball Players.
Аннотация
BACKGROUND
This study validates real-time biofeedback for lumbopelvic control training in baseball. The lumbopelvic region is crucial for generating kinetic energy in pitching. Real-time biofeedback enhances training effectiveness and reduces injury risk. The validity and reliability of this system were examined.
PURPOSE: This study was to investigate the validity and reliability of the real-time biofeedback system for lumbopelvic control training.
METHODS
Twelve baseball players participated in this study, with data collected in two sessions separated by a week. All participants needed to do the lateral slide exercise and single-leg squat exercise in each session. Pelvic angles detected by the real-time biofeedback system were compared to the three-dimensional motion capture system (VICON) during training sessions. Additionally, pelvic angles measured by the biofeedback system were compared between the two training sessions.
RESULTS
The real-time biofeedback system exhibited moderate to strong correlations with VICON in both exercises: lateral slide exercise (r = 0.66-0.88, p < 0.05) and single-leg squat exercise (r = 0.70-0.85, p < 0.05). Good to excellent reliability was observed between the first and second sessions for both exercises: lateral slide exercise (ICC = 0.76-0.97) and single-leg squat exercise (ICC = 0.79-0.90).
CONCLUSIONS
The real-time biofeedback system for lumbopelvic control training, accurately providing the correct pelvic angle during training, could enhance training effectiveness.