MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/mus.21210

Медицинская библиотека · Muscle & nerve · 2009

Reliability of quantitative sudomotor axon reflex testing and quantitative sensory testing in neuropathy of impaired glucose regulation.

Peltier Amanda, Smith A Gordon, Russell James W, Sheikh Kiran, Bixby Billie, Howard James, Goldstein Jonathan, Song Yanna, Wang Lily, Feldman Eva L, Singleton J Robinson

Клиническое исследованиеСтатьяМногоцентровое исследованиеПоддержка NIH: внешняя программаПоддержка правительства СШАВалидационное исследованиеПеревод пока не подготовлен

Аннотация

Reproducible neurophysiologic testing paradigms are critical for multicenter studies of neuropathy associated with impaired glucose regulation (IGR), yet the best methodologies and endpoints remain to be established. This study evaluates the reproducibility of neurophysiologic tests within a multicenter research setting. Twenty-three participants with neuropathy and IGR were recruited from two study sites. The reproducibility of quantitative sudomotor axon reflex test (QSART) and quantitative sensory test (QST) (using the CASE IV system) was determined in a subset of patients at two sessions, and it was calculated from intraclass correlation coefficients (ICCs). QST (cold detection threshold: ICC=0.80; vibration detection threshold: ICC=0.75) was more reproducible than QSART (ICC foot=0.52). The performance of multiple tests in one setting did not improve reproducibility of QST. QST reproducibility in our IGR patients was similar to reports of other studies. QSART reproducibility was significantly lower than QST. In this group of patients, the reproducibility of QSART was unacceptable for use as a secondary endpoint measure in clinical research trials.

Для цитирования: Peltier Amanda, Smith A Gordon, Russell James W, Sheikh Kiran, Bixby Billie, Howard James, Goldstein Jonathan, Song Yanna, Wang Lily, Feldman Eva L, Singleton J Robinson. Reliability of quantitative sudomotor axon reflex testing and quantitative sensory testing in neuropathy of impaired glucose regulation.. Muscle & nerve. 2009. DOI: 10.1002/mus.21210.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.